2007-01-05 11:09:43PERMIT: 06110096
 ADD: 2247 PALM BEACH LAKES BLVD,SUITE 105
 CONT: AMODIE ENGINEERING & CONSTRUCTION
 TEL: (561)685-7500
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 2) 2ND REQUEST, 110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) COMPLIED.
 B) COMPLIED.
  
 C) THE TYPE OF CONSTRUCTION"FOR THE BUILDING"
 AS DEFINED IN CHAPTER 6, TABLE 503.
 THIS WILL DEFINE WHAT MATERIALS WILL OR WILL
 NOT BE ALLOWED IN THIS STRUCTURE.
 THE RESPONCE INDICATED A TYPE V BUILDING NOT INDICATING
 A OR B,
 AND TO THE ANSWER TO QUESTION "E" SPRINKLERS NOT
 REQUIRED.
 THIS BUILDING IS APPROX 12,500 SQ FT IN FOOTPRINT,
 TABLE 503ONLY ALLOWS 9.000SF
 FOR A TYPE V-B BUILDING. EITHER THIS IS A TYPE V-A OR
 TYPE V-B WITH AREA INCREASES
 OR THE AREA INCREASES FOR FIRE SPRINKLERS.
  
 D) COMPLIED.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 G) COMPLIED.
 H) LEVEL OF ALTERATIONS? 2004 EXISTING BUILDING CODE,
 SEE LEVEL 2, CHAPTER II.
  
 3) COMPLIED.
  
 4) COMPLIED.PRIVATE RESTROOMS ARE TO BE
 ADAPTABLE.11-4.1.3(11)
 ( REQUIRES BACKING IN WALLS.)
  
 5) 2ND REQUEST, YOUR RESPONCE TO A BREAK ROOM SINK
 VS A WORK SINK, WHAT TYPE OF WORK WILL BE ACCOMPLISHED
 THAT WILL TRANSFORM THISFROM A BREAK ROOM SINK TO A
 WORK SINK?
 WHEN THE E SHEETS SHOW THERE TO BE AN UNDER COUNTER
 REFRIGARATOR AND A GARBAGE DISPOSAL
 IT APPEARS THIS IS TRUELY A BREAK ROOM SINK.
 PLEASE SEE,11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
  
 6) COMPLIED.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  