2006-11-27 07:41:00BUILDING PLAN REVIEW
 PERMIT: 06110096
 ADD: 2247 PALM BEACH LAKES BLVD,SUITE 105
 CONT: AMODIE ENGINEERING & CONSTRUCTION
 TEL: (561)685-7500
  
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 2)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 G ) NUMBER OF FLOORS
 H) LEVEL OF ALTERATIONS?
  
 3) FP-1 INDICATES ALL INTERIOR WALLS ARE NEW, PLEASE
 INDICATE WHAT EACH ROOM WILL BE USEDFOR?
  
 4) THE PLUMBING RISER INDICATES THERE IS A RETSROOM
 WITHIN THE
 UNIT, PLEASE SEE 11-4.22.2 DOORS.
 (1)ALL DOORS TO ACCESSIBLE TOILET ROOMS SHALL
 COMPLY WITH SECTION
 11-4.13 . DOORS SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACE REQUIRED
 FOR ANY FIXTURE. ALSO SEE 11-4.22 THE MINIMUM
 REQUIREMENTS FOR TOLIET ROOMS.
  
 5) THE PLUMBING ISOMETRIC ALSO APPEARS TO HAVE POSSIBLY
 A BREAK ROOM SINK,
 PLEASE SEE,11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
  
  
 6) PLEASE ALSO SEE THE MINIMUM REQUIRED CLEARENCES AT
 DOORS:
 11-4.13.6 MANEUVERING CLEARENCES
 AT DOORS. MINIMUM MANEUVERING CLEARANCES
 AT DOORS THAT ARE NOT AUTOMATIC OR
 POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITH
 IN THE REQUIRED CLEARANCES SHALL BE
 CLEAR & LEVEL.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  