| Plan Review Notes For Permit 06101140 |
| Permit Number |
06101140 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-01-10 18:00:15 | BUILDING REVISION CHECKLIST: | | | 1- FLAT ROOF ASSEMBLY: CLEARLY IDENTIFY WHICH APPROVED | | | FLAT ROOF ASSEMBLY OF NOA 03-0827.02 IS GOING TO BE | | | INSTALLED. AS REQUIRED BY CITY POLICY FOR ROOFING | | | PERMITS. SEE ATTACHED COPY. | | | | | | 2- FROM SELECTED ASSEMBLY CLEARLY IDENTIFY WHICH BASE | | | SHEET FASTENING OPTION IS GOING TO BE INSTALLED AS | | | REQUIRED BY CITY POLICY FOR ROOFING PERMITS. | | | | | | 3- IF SELECTED ASSEMBLY IS LIMITED BY GENERAL | | | LIMITATION, THEN NEED TO PROVIDE RAS 117 CALCULATIONS | | | FOR NAIL ENHANCING AT PERIMETER AND CORNER AREAS. | | | CALCULATIONS NEED TO BE SIGNED AND SEALED BY ARCHITECT, | | | ENGINEER OR REGISTERED ROOFING CONSULTANT AS REQUIRED | | | BY GENERAL LIMITATION #7. SEE PAGE PAGE OF NOA | | | SUBMITTED. | | | | | | 4- IF SELECTED SYSTEM IS LIMITED BY GENERAL LIMITATION | | | #9, THEN IT MAY NOT BE USED IN THIS AREA BECAUSE THE | | | DESIGN PRESSURES FOR WHICH SYSTEM IS DESIGNED MAY NOT | | | BE ENOUGH FOR THIS AREA. SEE TABLE R301.2(2) 2004 | | | FLORIDA RESIDENTIAL CODE. | | | | | | 5- OWES $47.25 FOR UPDATED VALUE TO INCLUDING FLAT | | | ROOF. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 | | | |
|