Plan Review Notes For Permit 06101118
Permit Number 06101118
Review Stop P
Sequence Number 2
Notes
Date Text
2007-02-17 07:00:16 
  
 PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN
 REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
  
 FBC 2004 CH 11, FL ACESSIBILITY CODE
  
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 DENIED
  
 1)106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL (SEE ALSO SECTION
 106.3.5).
  
 2)TAB 1004.1.2 PROVIDE OCCUPANT LOAD
  
 3)MINIMUM PLUMBING FACILITIES
 403.1 MINIMUM NUMBER OF FIXTURES.
 PLUMBING FIXTURES SHALL BE PROVIDED FOR THE TYPE OF
 OCCUPANCY AND IN THE MINIMUM NUMBER SHOWN IN TABLE
 403.1. TYPES OF OCCUPANCIES NOT SHOWN IN TABLE 403.1
 SHALL BE CONSIDERED INDIVIDUALLY BY THE CODE OFFICIAL.
 THE NUMBER OF OCCUPANTS SHALL BE DETERMINED BY THE
 FLORIDA BUILDING CODE, BUILDING. OCCUPANCY
 CLASSIFICATION SHALL BE DETERMINED IN ACCORDANCE WITH
 THE FLORIDA BUILDING CODE, BUILDING.
  
 4)(10) DRINKING FOUNTAINS.
 (A) WHERE ONLY ONE DRINKING FOUNTAIN IS PROVIDED ON A
 FLOOR, THERE SHALL BE A DRINKING FOUNTAIN WHICH IS
 ACCESSIBLE TO INDIVIDUALS WHO USE WHEELCHAIRS IN
 ACCORDANCE WITH SECTION 11-4.15 AND ONE ACCESSIBLE TO
 THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. (THIS
 CAN BE ACCOMMODATED BY THE USE OF A ?HI-LO? FOUNTAIN;
 BY PROVIDING ONE FOUNTAIN ACCESSIBLE TO THOSE WHO USE
 WHEELCHAIRS AND ONE FOUNTAIN AT A STANDARD HEIGHT
 CONVENIENT FOR THOSE WHO HAVE DIFFICULTY BENDING; BY
 PROVIDING A FOUNTAIN ACCESSIBLE UNDER SECTION 11-4.15
 AND A WATER COOLER; OR BY SUCH OTHER MEANS AS WOULD
 ACHIEVE THE REQUIRED ACCESSIBILITY FOR EACH GROUP ON
 EACH FLOOR.)
  
  
 5) PRIVATE BATHROOM, TO BE ADAPTIBLE, SEE FIG 35
 SHOWER SIZE AND CLEARANCE.
 (11) TOILET FACILITIES. IF TOILET ROOMS ARE PROVIDED,
 THEN EACH PUBLIC AND COMMON USE TOILET ROOM SHALL
 COMPLY WITH SECTION 11-4.22. OTHER TOILET ROOMS
 PROVIDED FOR THE USE OF OCCUPANTS OF SPECIFIC SPACES
 (I.E., A PRIVATE TOILET ROOM FOR THE OCCUPANT OF A
 PRIVATE OFFICE) SHALL BE ADAPTABLE. IF BATHING ROOMS
 ARE PROVIDED, THEN EACH PUBLIC AND COMMON USE BATHROOM
 SHALL COMPLY WITH SECTION 11-4.23. ACCESSIBLE TOILET
 ROOMS AND BATHING FACILITIES SHALL BE ON AN ACCESSIBLE
 ROUTE.
  
 6)SEE OTHER PLAN REVIEW COMMENTS, THAT MAY EFFECT
 PLUMBING PLAN REVIEW.
  
 END OF COMMENTS, QUESTIONS 561-805-6692
  