| Plan Review Notes For Permit 06101112 |
| Permit Number |
06101112 |
|
| Review Stop |
B |
| Sequence Number |
5 |
|
| Notes |
| Date |
Text |
| 2007-07-10 10:31:38 | TRUSS PACKAGE CHECKLIST: | | | 1-A) ONLY TWO SETS WERE SUBMITTED. THIS TYPE OF | | | PROJECT REQUIRES THREE COMPLETE SETS.THREE SIGNED AND | | | SEALED SETS AS REQUIRED BY CHAPTER 471 FLORIDA STATUTE | | | AND SEC. 61G15-23 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | B) TRUSS ENGINEER TO PROVIDE ALL THREE SETS WITH | | | ORIGINAL SIGNATURE. COPY OF SIGNATURE IS NOT ALLOWED BY | | | CHAPTER 471 FLORIDA STATUTE. | | | | | | C) EVERY INDIVIDUALSHEETNEEDS TO HAVE | | | ENGINEER'S ORIGINAL SEAL, SIGNATURE AND DATE. | | | OTHERWISE, ENGINEER MAY WANT TO FOLLOW ALL CONDITIONS | | | REQUIREDBY SEC. 61G15-31.003 FLORIDA ADMINISTRATIVE | | | CODE TO COMPLY WITH THE SIGNING AND SEALING OF ALL | | | SHEETS.INFORMATION SUBMITTED DOESN'T COMPLYWITH | | | THIS SECTION. | | | | | | | | | 2- ENGINEER OF RECORD DESIGNED FLOOR TRUSSES TO BE | | | RESTING ON TOP CHORD.TRUSS PACKAGE SHOWS FLOOR | | | TRUSSES RESTING ON A TRUSS HANGER SUPPORTING TRUSS ON | | | BOTTOM CHORD. REVISE EITHER TRUSS PACKAGE OR ENGINEERED | | | DRAWINGS AS REQUIRED TO MATCH. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|