Plan Review Notes
Plan Review Notes For Permit 06101081
Permit Number 06101081
Review Stop B
Sequence Number 4
Notes
Date Text
2007-10-31 14:29:34BUILDING PLAN REVIEW
 PERMIT: 06101081
 ADD: 2905 45TH ST
 CONT: FIRST FLORIDA CONSTRUCTION
 TEL: (813)881-0607
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1) PLANS HAVE WHITE OUT USED ONSHEETS2 & 4.
 104.2.1.3 THE BUILDING OFFICIAL
 MAY SET STANDARDS THROUGH DEPARTMENTAL
 POLICY STANDARDS FOR PLANS AND SPRCIFICA
 TIONS. "NO WHITE OUT".
  
 2) SHEET# 4 INDICATES EGRESS LIGHTS ON A 1000W
 DIMMER.1006.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL
 BE CONTINUOUS DURING THE TIME THAT THE CONDITIONS OF
 OCCUPANCY REQUIRE THAT THE MEANS OF EGRESS BE AVAILABLE
 FOR USE. ARTIFICIAL LIGHTING SHALL BE EMPLOYED AT SUCH
 PLACES AND FOR SUCH PERIODS OF TIME AS REQUIRED TO
 MAINTAIN THE ILLUMINATION TO THE MINIMUM CRITERIA
 VALUES HEREIN SPECIFIED. EXCEPTIONS: AUTOMATIC MOTION
 SENSOR-TYPE LIGHTING SWITCHES SHALL BE PERMITTED WITHIN
 THE MEANS OF EGRESS, PROVIDED THAT SWITCH CONTROLLERS
 ARE EQUIPPED FOR FAIL-SAFE OPERATION, ILLUMINATION
 TIMERS ARE SET FOR A MINIMUM 15-MINUTE DURATION AND THE
 MOTION SENSOR IS ACTIVATED BY ANY OCCUPANT MOVEMENT IN
 THE AREA SERVED BY THE LIGHTING UNITS.
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
  
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  