Plan Review Notes
Plan Review Notes For Permit 06101055
Permit Number 06101055
Review Stop P
Sequence Number 2
Notes
Date Text
2006-12-29 15:04:56DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 BUILDING
 FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FHA-98 DESIGN MANUAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 NOTE: 1ST REVIEW UNDER PERMIT
  
 **********FROM PREVIOUS REVIEW**********
  
 1. SHEETS DELETED. WILL BE SUBMITTED AT THE TIME OF
 APPLICATION SUBMITTAL PER RESPONSE.
  
 2. OK
 3. OK
 4. OK
 5. DELETED
 6. OK
 7. OK
 8. OK
 9.OK NOT REQUIRED FOR THIS BUILDING.
 10. OK NOT REQUIRED THIS BUILDING.
 11. OK
 12. OK
 13. OK (UNIT LOCATION ONLY)
 14. OK. NOT REQUIRED FOR THIS BUILDING.
 15. OK. NOT REQUIRED FOR THIS BUILDING.
 16. OK. NOT REQUIRED FOR THIS BUILDING.
 17. OK. NOT REQUIRED FOR THIS BUILDING.
 18. OK. NOT REQUIRED FOR THIS BUILDING.
 19. OK. NOT REQUIRED FOR THIS BUILDING.
 20. OK. NOT REQUIRED FOR THIS BUILDING.
 21. OK. NOT REQUIRED FOR THIS BUILDING.
  
 22. SHTS P201 & P202 PLAN KEY NOTE #2 INDICATES
 KITCHEN SINK ARM IS RUN UNDER THE SLAB,
 BUT THE 3S RISER DIAGRAM ON SHT P402
 INDICATES THE SINK ARM IS ABOVE THE SLAB
 PLEASE CLARIFY AND CORRELATE THE NOTES,
 FLOOR PLAN, AND RISER DIAGRAM. SECTION
 106.1.1.
 ****RESPONSE NOTED. NO ACTION TAKEN.
 ****NO RESPONSE, NOT ADDRESSED
  
 23. OK
 24. OK. (GAS NOTE)
 25. OK. NOT REQUIRED FOR THIS BUILDING
 26. OK
  
 27. SUBMIT A BUILDING DRAIN SANITARY
 RISER DIAGRAM ISOMETRIC THAT REFLECTS
 THE FLOOR PLAN FOR EACH BUILDING.
 SECTION 106.1.5.1.3. SHOW ALL PIPE
 SIZES, RISER LOCATIONS, TRAPS, VENTS,
 AND DFU'S AS THEY ACCUMULATE IN THE
 SYSTEM.
 ****RESPONSE NOTED. RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN. CLEANOUT AT THE BACK OF THE BUILDING NOT
 SHOWN. SHOW CLEANOUTS REQUIRED BY SECTION 708.3.3,
 CHANGE OF DIRECTIONGREATER THAN 45 DEGREES.
 ****RESPONSE NOTED, BUT THE CLEANOUT AT THE BACK OF THE
 BUILDING SHOWN ON THE FLOOR PLAN IS STILL NOT SHOWN ON
 THE RISER DIAGRAM.
  
 28. OK
 29. OK. NOT REQUIRED THIS BUILDING.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 SUBMIT ONE SET OF PLANS FROM FIRST
 REVIEW FOR COMPARISON TO EXPEDITE 2ND
 REVIEW.
  
 **************NEW COMMENTS**************
  
 1B. OK
 2B. OK
 3B. OK
  
 4B. SEPARATE GAS PERMIT REQUIRED. SUBMIT THE FOLLOWING
 INFORMATION:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. AN ISOMETRIC IS REQUIRED FOR EACH GAS
 SYSTEM SHOWING THE PIPING FROM THE METER TO THE MOST
 REMOTEAPPLIANCE FOR EACH UNIT.
  
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE IF BEING USED.
  
 C. TYPE OF GAS, (LP OR NATURAL).
  
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33).
  
 E. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 F. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
  
 G. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
  
 H. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505.
  
 I. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2
  
 ****RESPONSE NOTED, ALL INFORMATION/PLANS TO BE
 SUBMITTED WITH GAS PERMIT APPLICATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]