2006-11-17 13:36:04*** PROVISO ***
 1) UNITS (A1) UPPER AND LOWER,RETURN AIR TRANSFER
 GRILLS TO MASTER BEDROOM SUITE NEED TO BE 14"X 8", SEE
 2004 FBC/M 601.4.
  
 2) CLOTHES DRYER VENTS MAY NOT EXCEED THE
 MANUFACTURER'S SPECIFICATION'S.
  
 3) AHU CLOSET DOORS NEED TO BE LOUVERED OR GRILLS NEED
 TO BE INSTALLED FOR RETURN AIR, SEE 2004 FBC/M 601.4.
  
 4) LAUNDRY ROOM DOORS NEED TO BE LOUVERED OR GRILLS
 NEED TO BE INSTALLED FOR COMBUSTION AIR, SEE 2004 FBC/M
 701.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.