Plan Review Notes
Plan Review Notes For Permit 06101014
Permit Number 06101014
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2006-11-21 12:08:36*****DENIED*****
  
  
  
 01.PLEASE PROVIDE A LAYOUT OF THE STRUCTURE ON A SITE
 PLAN AS TO HOW IT RELATES TO THE NEAREST STREETS,
 HYDRANTS, RAILROAD, ETC.
  
 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 03.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL
 NOT HINDER OR INTERFERE WITH EMERGENCY ACCESS TO THE
 SAID PROPERTY OR VICINITY THEREOF.
  
 04.FIRE EXTINGUISHERS TO BE RATED 2A-10 BC.
  
 05.PLEASE BE ADVISED THAT SMOKE DETECTORS (SD) ARE
 TIED INTO A FIRE ALARM SYSTEM.THE DEVICES USED AT THE
 SITE ARE SMOKE ALARMS (SA) AND SHOULD BE REFLECTED AS
 SUCH IN THE SUBMITTED PLANS.
  
 06.FOR SPECIFIC LOCATION REQUIREMENTS OF SMOKE
 ALARMS/SMOKE DETECTORS, NFPA 72 - 2002 EDITION -
 11.8.3.5 SHALL BE REFERENCED.
  
 07.SMOKE ALARMS INSTALLED WITHIN 20-FT HORIZONTAL
 PATH OF A COOKING APPLIANCE SHALL BE EQUIPPED WITH AN
 ALARM SILENCING MEANS OR BE OF THE PHOTOELECTRIC TYPE.
  
 08.SMOKE ALARMS SHALL RECEIVE ITS OPERATING POWER
 FROM THE BUILDING'S ELECTRICAL SERVICE.
  
 09.INSTALL A SMOKE ALARM IN THE LIVING AREA OF THE
 UNITS.
  
 10. INTERIOR FINISH FOR WALLS AND CEILING SHALL BE
 CLASS "A" OR CLASS "C".PLEASE SPECIFY.
  
 11. VERITY THAT THE NUMERICAL ADDRESS (ON THE BUILDING)
 IS NO LESS THAN 6" IN HEIGHT AND 1" IN WIDTH PLAINLY
 VISIBLE FROM 16TH STREET.EACH UNIT SHALL HAVE A
 NUMBER OR ALPHABET NO LESS THAN 3" IN HEIGHT ABOVE OR
 IN THE VICINITY OF THE FRONT DOOR (NOT ON THE DOOR).
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED
  
  