2007-10-26 16:41:08BUILDING PLAN REVIEW
 PERMIT: 06100956
 ADD: 2380 PALM BEACH LAKES BLVD
 CONT: COLUMBIA CONSTRUCTION
 TEL: (321)246-4825
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVISION# 18 SHEET C3REVIEW
 ACTION: DENIED
  
 1)THE ORIGINAL PERMITTED PLANS INDICATED AN ACCESSIBLE
 ROUTE FROM THE PUBLIC WAY TO THE FRONT OF THE BUILDING.
 REVISION# 18 NOW INDICATES APPROXIMATELY 2'-0"
 DIFFERENCE IN GRADE AND EXTERIOR STAIRS.
 THE REVISION FAILS TO SHOW "EQUIVALENT FACILITATION"
 11-2.2 WHICH WILL REQUIRE A DISABLED PERSON TO HAVE TO
 USE THE DISABLED ACCES POINT BEHIND THE BUILDING. IF
 THE GRADE DIFFERENCE IN FRONT WAS MADE UP THROUGH AN
 ACCESSIBLE RAMP WTIH THE CORRECT SLOPE HANDRAILS AND
 LANDINGS BOTH DISABLED AND THOUGHS NOT DISSABLED WOULD
 BE ABLE TO USE THE FRONT ACCESSBLE ENTRY ROUTE.
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE
 APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  