| 2006-12-16 07:12:33 | PAUL SCHMITZ |
| | [email protected] FBC 2004 PLUMBING |
| | CODE PLAN REVIEW |
| | FBC2004 FUEL GAS CODEPLAN REVIEW |
| | FBC 2004 CH 11, FL ACESSIBILITY CODE |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE |
| | CHAPT.1, ADMINISTRATION, 2004 EDITION |
| | |
| | DENIED,PROJECT, PLAN REVIEW ONLY. |
| | |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) |
| | PLANS SHALL BE ROUTED TO DBPR |
| | BUSINESS AND HOTEL DIVISION FOR |
| | REVIEW. MINIMUM 2 SETS OF PLANS |
| | SHALL BE REVIEWED AND STAMPED |
| | AND THE TWO PAGE ?WORKSHEETS? |
| | ATTACHED TO EACH SET OF PLANS |
| | PRIOR TO RESUBMITTING TO CITY OF WEST PALM BEACH FOR |
| | REVIEW. PLEASE CONTACT DBPR |
| | AT (850) 487-1395. |
| | |
| | 3) SHT P 200, GREASE TRAP SIZE. TO BE CONFIRMED BY |
| | CONTACT W P BEACHWATERPLANT LAB SUPERVISOR |
| | INDUSTRIAL COORDINATOR, LYNN MASSON |
| | |
| | OFFICE 561-822-2271E-MAIL [email protected] |
| | |
| | 4)SHT A-000 NUMBER OF REQUIRED PLUMBING FIXTURES |
| | 403.1 MINIMUM NUMBER OF FIXTURES. |
| | PLUMBING FIXTURES SHALL BE PROVIDED FOR THE TYPE OF |
| | OCCUPANCY AND IN THE MINIMUM NUMBER SHOWN IN TABLE |
| | 403.1. TYPES OF OCCUPANCIES NOT SHOWN IN TABLE 403.1 |
| | SHALL BE CONSIDERED INDIVIDUALLY BY THE CODE OFFICIAL. |
| | THE NUMBER OF OCCUPANTS SHALL BE DETERMINED BY THE |
| | FLORIDA BUILDING CODE, BUILDING. OCCUPANCY |
| | CLASSIFICATION SHALL BE DETERMINED IN ACCORDANCE WITH |
| | THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 403.5 LOCATION OF EMPLOYEE TOILET FACILITIES IN |
| | MERCANTILE AND ASSEMBLY OCCUPANCIES. |
| | EMPLOYEES SHALL BE PROVIDED WITH TOILET FACILITIES IN |
| | BUILDING AND TENANT SPACES UTILIZED AS RESTAURANTS, |
| | NIGHTCLUBS, PLACES OF PUBLIC ASSEMBLY AND MERCANTILE |
| | OCCUPANCIES. THE EMPLOYEE FACILITIES SHALL BE EITHER |
| | SEPARATE FACILITIES OR COMBINED EMPLOYEE AND PUBLIC |
| | FACILITIES. THE REQUIRED TOILET FACILITIES SHALL BE |
| | LOCATED NOT MORE THAN ONE STORY ABOVE OR BELOW THE |
| | EMPLOYEES? WORK AREA AND THE PATH OF TRAVEL TO SUCH |
| | FACILITIES, IN OTHER THAN COVERED MALLS, SHALL NOT |
| | EXCEED A DISTANCE OF 500 FEET (152 M). THE PATH OF |
| | TRAVEL TO REQUIRED FACILITIES IN COVERED MALLS SHALL |
| | NOT EXCEED A DISTANCE OF 300 FEET (91 M). |
| | |
| | 403.1.1 POTTY PARITY. |
| | IN ASSEMBLY OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO |
| | THE PUBLIC MUST HAVE A RATIO OF 3:2 WATER CLOSETS |
| | PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER |
| | CLOSETS AND URINALS PROVIDED FOR MEN, UNLESS THESE ARE |
| | TWO OR FEWER SUCH FIXTURES FOR MEN, IN ACCORDANCE WITH |
| | ?553.86, FLORIDA STATUTES. |
| | |
| | 5) SHT P-100 DETAIL 7PLUMBING ISOMETRIC |
| | SEC 606.1 LOCATION OF FULL-OPEN VALVES. |
| | FULL-OPEN VALVES SHALL BE INSTALLED IN THE FOLLOWING |
| | LOCATIONS: |
| | ONTHE TOP OF EVERY WATER DOWN-FEED PIPE IN OCCUPANCIES |
| | OTHER THAN ONE- AND TWO-FAMILY RESIDENTIAL |
| | OCCUPANCIES. |
| | |
| | 6)SHT P100 SEC 604.9 WATER HAMMER. |
| | THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM |
| | SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER |
| | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE INSTALLED |
| | WHERE QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER |
| | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE |
| | MANUFACTURER?S SPECIFICATIONS. WATER-HAMMER ARRESTORS |
| | SHALL CONFORM TO ASSE 1010. |
| | |
| | 7)SHT P- 100, 110 PLAN NOTES #1, #9 REFERENCE TO TO |
| | SITE UTILITY PLANS. |
| | SITE PLANS NOT INCLUDED. |
| | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL (SEE ALSO SECTION |
| | 106.3.5). |
| | |
| | 8)PLEASE SEE ANY POSSIBLE COMMENTS FROM |
| | OTHER TRADES WHICH MAY AFFECT PLUMBING |
| | PLANS. |
| | |
| | END OF COMMENTS, QUESTIONS; 561-805-6692 |