| 2007-06-18 15:44:14 | PERMIT: 06100891 |
| | ADD: 2395 NORTHWOOD UNIVERSITY DR. |
| | CONT: THE WEITZ CO. |
| | TEL: (561309-7386 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RDREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2 ) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 3A) NEW ARCHITECTURAL SHEETS WERE ADDED AS REVISION# 2 |
| | DATED 3/13/07 THE COVERSHEET,A2.2,A4.01, A4.11,& |
| | A4.23 PLEASE SEE THAT THE SIGNATURE ON THESE SHEETS IS |
| | DIFFERENT FROM THE PREVIOUS SHEETS, |
| | AND ALSO SEE THE FIRMS SEAL WAS USED INSTEAD OF THE |
| | DESIGN PROFESSIONAL JAMES HOWELL. NOTE ONE SET OF PLANS |
| | WILL BE RETAINED FOR POSSIBLE SUBMITTAL TO THE STATE OF |
| | FLORIDA AND BOARD OF ARCHITECTS. |
| | |
| | 3B) PLEASE HAVE THE SIGNATURE SHEET FORMERLY SUBMITTED, |
| | SEALED WITH THE CORRECT SEAL BY THE DESSIGN |
| | PROFESSIONAL JAMES HOWELL AND THE NOTARYAFFIX THE |
| | PROPER WORDAGE & DATE REQUIRED UNDER THE PROVISIONS OF |
| | THE NOTARY AGREEMENT WITH THE STATE OF FLORIDA. |
| | |
| | 4) COMMENT# 8 FROM THE 2NDREVIEW;FBC* 105.3 |
| | RESIDENT INSPECTOR. SUBMIT INSPECTOR RESUME' AND |
| | LICENSE DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF THE |
| | RESIDENT INSPECTOR PROGRAM.A RESIDENT INSPECTOR |
| | PROGRAM IS REQUIRED, ON THIS PROJECT, DUE TO ONE OR |
| | MORE OF THE FOLLOWING: |
| | |
| | XX - BUILDINGS/ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | - ANY MAJOR STRUCTURAL ALTERATIONS |
| | - STRUCTURES IN WHICH THE CONCRETE |
| | DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F'C) IN EXCESS OF 3000 PSI |
| | - PILE DRIVING |
| | - BUILDINGS OVER 20,000 SQFT IN AREA |
| | - BUILDINGS OVER 2 STORIES IN HEIGHT |
| | - BUILDING/STRUCTURES OF UNUSUAL DESIGN |
| | OR METHODS OF CONSTRUCTION |
| | |
| | 5) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. |
| | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL |
| | BE PERMORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT |
| | THE CONDITION OF ADJACENT PROPERTY, UNLESS |
| | SUCH ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY |
| | PURSUANT TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, |
| | UNDER TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE |
| | PROPERTY OWNER.THIS INCLUDESBUT IS NOT LIMITED TO THE |
| | CONTROL OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, |
| | DEBRIS, AND THE STORAGE OF CONSTRUCTION MATERIALS. NEW |
| | CONSTRUCTION ACTIVITY SHALL NOT ADVERSELY IMPACT |
| | HISTORICSURFACE WATER DRAINAGE FLOWS SERVING ADJACENT |
| | PROPERTIES, & MAY REQUIRE SPECIAL DRAINAGE DESIGN |
| | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE |
| | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, |
| | DEVELOPERS, CONTRACTORS,AND OWNERS OF ALL NEW |
| | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ |
| | FT OF PERMEABLE LAND AREA ON ANY PARCELL SHALL |
| | AS A PERMIT CONDITION, PROVIDE A PROFESSIONALLY |
| | PREPARED DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE |
| | WITH THIS PARAGRAPH. UPON COMPLETION OF THE |
| | IMPROVEMENT, A CERTIFICATE FROM A LICENSED ENGINEER |
| | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE |
| | APPROVAL OF THE FINAL INSPECTION. |
| | |
| | 6) BUILDING PROVISO:109.3.10.1 HURICANE PROTECTION. |
| | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW |
| | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO |
| | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN |
| | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN |
| | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION |
| | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE |
| | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH |
| | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR |
| | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS |
| | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED |
| | SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN |
| | ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO |
| | VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE |
| | PURSUANT TO SECTION 113 OF THIS CHAPTER. |
| | |
| | 7) PROVISO: THE BUILD OUT FOR THE EXCHANGE CITY AND THE |
| | FINANCE PARK WILL BE UNDER SEPERATE PERMIT. |
| | |
| | |
| | 8)NOTE THIRD REVIEW, NOT A SINGLE PRODUCT APPROVAL |
| | WAS SUBMITTED.FL BLD CODE 1609.1.4: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT |
| | INSPECTOR) OF PRODUCT TESTING REPORTS,MISSING REPORTS |
| | ARE AS FOLLOWS: |
| | 1) FIXED WINDOWS- STOREFRONT |
| | 2) OPERTABLE WINDOWS |
| | 3) GLAZED DOORS, BOTH SWING AND SLIDE |
| | 4) METAL HOLLOW CORE EXTERIOR DOORS & LOUVERS. |
| | 5) PRE-ENGINEERED ROOF ACCESS HATCHES |
| | 6) MULLIONS VERTICAL & HORIZONTAL |
| | 7) EXTERIOR ROLL UP, OR SECTIONAL DOOR |
| | 8) SKYLIGHTS |
| | 9)PANEL WALL SYSTEMS: SIDING, SOFFITS, EFIS |
| | SYSTEMS, LOUVERS |
| | 9)ROOFING ASSEMBLIES, |
| | 10) PRE-ENGINEERED ROOF STANDS |
| | |
| | 9)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |