| 2006-10-30 08:58:05 | DENIED |
| | |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE |
| | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY |
| | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF |
| | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT |
| | COMMENCED WITHIN 90 DAYS OF RECORDING. |
| | |
| | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.BASED ON ICC BUILDING VALUATION DATA THE PERMIT |
| | VALUE HAS BEEN REVISED TO $231,505 .ADDITIONAL PERMIT |
| | FEES ARE DUE PRIOR TO RESUBMITTING. |
| | |
| | 4.SIGN OWNER/AGENT ON ENERGY CALCS PER 2004 FBC. |
| | |
| | 5.PRODUCT APPROVALS REQUIRED FOR LINTELS AND STRAPS |
| | AND TIE-DOWNS. |
| | |
| | 6.HAND DRAWN CHANGES NOT PERMITTED ON PLANS, FBC |
| | 106.1.3 |
| | |
| | 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. |
| | |
| | |
| | 8.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER |
| | 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE |
| | APPROVED PRIOR TO INSTALLATION. |
| | |
| | 9.HOUSE DATA SHOULD INCLUDE COVERED PORCH AREA. |
| | |
| | 10.R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| | OF 6 INCHESWITHIN THE FIRST 10 FEET. |
| | |
| | 11.REPRINT PAGE 5 OF 6.IT IS NOT COMPLETELY |
| | LEDGABLE. |
| | |
| | 12.HAND RAIL HEIGHT IS INCORRECT AND SHOULD COMPLY |
| | WITH R-311.5.6.1 |
| | |
| | 13.SHOW WALL SHEATHING NAILING SCHEDULE. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE |
| | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET |
| | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | |
| | |