| Plan Review Notes For Permit 06100574 |
| Permit Number |
06100574 |
|
| Review Stop |
ENG |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-11-03 13:46:55 | PLEASE PROVIDE FOLLOWING INF: | | | 1. CITY OF WPB STANDARD NOTES ON DRAWING FOR PARKING, | | | HANDICAP PARIKG PAINTED PER CITY CODES ETC.,, MUST MEET | | | PER ADA,,SIDEWALK WIDTH, ITS SLOPE, | | | 2. DUMPSTER LOCATION ON DWG, MUST BE ACCESSIBLE FOR | | | PICKUP TRUCK. | | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | | ON THE DRAWINGS. | | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT | | | 5. PLEASE SHOW HOW DID YOU CALCULATE LENGTH OF | | | EXFILTRATION TRENCH LENGTH,WHAT IS FACOR OF | | | SAFETY?,WHAT CRITERIA YOU ASSUME , LIKE 1" OVER ENTIRE | | | SITE OR 2.5"CRITERIA, WHICH CRITERIA YOU USED. | | | PLEASE SHOW CALCULATIONS. | | | 6. WHAT IS THE SITE AREA, PERVIOUS AREA, IMPERVIOUS | | | AREA, PLEASE SHOW RUNOFF CAL & CRITERIA YOU USED. 7. | | | STORM WATER FROM CONTROL STRUCTURE GOES TOBANYAN | | | BLVD, THERE IS ANOTHER CROSSING STORM WATER PIPE BEFORE | | | YOU CONNECT TO THE STORM WATER PIPE., THERE ARE | | | COUPLE OF STORM PIPIE RUNNING ON BANYAN NOT SHOW | | | CLEARLY.PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR | | | SITE SO, WE CAN DETERMINE THE BEST PIPE TO CONNECT WITH | | | THE STORM WATER FROM ALL OTHER STORM WATER PIPES. | | | PLEASE SHOW DETAIL OF THE CONTROL STRUCTURES WITH | | | ELEVATIONS. | | | | | | RASIK CHOKSHI 805-6723 |
|