| Date |
Text |
| 2007-04-18 10:34:48 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FACFLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.)SEE ELECTRIC COMMENTS REGARDING "EXISTING" |
| | CONDITIONS.THE PERMIT 03052313 HAS A VOID STATUS DUE |
| | TO INACTIVITY.THIS PERMIT HAD ONLY ONE INSPECTION. |
| | THIS ISSUE MUST BE ADDRESSED PRIOR TO ISSUANCE OF THIS |
| | PERMIT.EITHER INCORPORATE THE WORK WHICH WAS |
| | COMPLETED INTO THIS PERMIT, OR APPLY FOR A SEPARATE |
| | PERMIT INCLUDING WORK THAT WAS COMPLETED BUT NOT |
| | FINALED. |
| | |
| | 2.)GOVERNING CODE IS FBC2004.SEVERAL SHEETS REFER |
| | TO FBC2001. |
| | |
| | 3.)SEE PREVIOUS LIST, ITEM 5, PEWS BLOCK THE EXIT. |
| | THE RESPONSE LETTER STATES THE PEWS ARE BEING REMOVED, |
| | BUT THEY STILL APPEAR ON S1.1. |
| | |
| | 4.)ACCESSIBILITY HAS NOT BEEN ADDRESSED IN THIS |
| | REVIEW AS DESIGNER HAS STATED THAT THIS BUILDING IS |
| | EXEMPT (CHURCH).NOTE THAT IF THE USE CHANGES, AND THE |
| | BUILDING IS OPEN TO THE PUBLIC, ALL ACCESSIBILITY |
| | REQUIREMENTS OF FBC11 APPLY. |
| | |
| | 5.)SEE DEFINITION OF AREA, BUILDING, FBC502.1.IT |
| | APPEARS THAT THE NORTH CHAPEL, SOUTH CHAPEL, AND |
| | KITCHEN ARE ONE BUILDING AS THEY ARE CONNECTED BY A |
| | COVERED PATIO.REVISE THE CODE ANALYSIS AS NECESSARY. |
| | ALSO NOTE THAT LEVEL 3 ALTERATION WAS DECLARED; THIS |
| | MAY CHANGE IF THE DECLARED BUILDING AREA INCREASES. |
| | |
| | 6.)S1.1, SEE FBC TABLE 1607.1.1(4), LIVE LOAD |
| | REQUIRED FOR THE FLOOR.50 IS SPECIFIED, 100 REQUIRED |
| | FOR MOVEABLE SEATS AND 125 REQUIRED FOR THE STAGE. |
| | |
| | 7.)A1.1 WALL TYPE 2 STATES "UNDERSIDE OF RATED |
| | FLOOR/CEILING ASSEMBLY".SHOW ALL REQUIRED FIRE |
| | RESISTANCE. |
| | |
| | 8.)SHOW THE RAMP RUN AND SLOPE.IT APPEARS TO HAVE A |
| | LANDING, BUT AS THE SLOPE IS NOT SHOWN IT IS NOT CLEAR |
| | THAT THIS IS A LANDING.ALSO SHOW WIDTH, EDGE |
| | PROTECTION. FBC1010.SHOW MANEUVERING CLEARANCE AT THE |
| | DOOR, FBC1010.6, SEE ALSO FBC11-4.8.4. |
| | |
| | 9.)WHEN RESUBMITTING, PLEASE SUBMIT OLD SHEETS. |
| | |
| | |
| | |
| | |