| Plan Review Notes For Permit 06100246 |
| Permit Number |
06100246 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-10-29 13:08:56 | BUILDING PLAN REVIEW | | | PERMIT:06100246 | | | ADD:8 CLOISTER CIR | | | CONT:OWNER BUILDER | | | TEL: (561)685-4987 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW1ST | | | ACTION: DENIED | | | | | | 1)2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 2)1609.1.3STRUCTURAL MEMBERS AND SYSTEMS AND | | | COMPONENTS AND CLADDING IN A BUILDING OR STRUCTURE | | | SHALL BE ANCHORED TO RESIST WIND-INDUCED OVERTURNING, | | | UPLIFT AND SLIDING AND TO PROVIDE CONTINOUS LOADS PATHS | | | FOR THESE FORCES TO THE FOUNDATION. PROVIDE SIGNED AND | | | SEAL PLANS SHOWING THAT THIS STRUCTURE WILL MEET THESE | | | REQUIREMENTS. WHY IS SAND AND GRAVEL USED INSTEAD OF | | | CONCRETE FOR THE POSTS. INDICATE THE SPECIFIC HURRICANE | | | STRAPS WHICH WILL BE USED. | | | | | | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD) MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | |
|