Plan Review Notes
Plan Review Notes For Permit 06100214
Permit Number 06100214
Review Stop B
Sequence Number 1
Notes
Date Text
2006-11-17 15:14:32BUILDING PLAN REVIEW
 PERMIT: 06100214
 ADD: 3654 GEORGIA AVE.
 CONT: INDUSTRIAL COMMERCIAL STRUCTURES
 TEL: (407)9484395
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 )FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) PLEASE PROVIDE A SITE PLAN PROVIDING THISTENANT
 LOCATION WITHIN THE BUILDING.
 106.1.2* ADDITIONAL INFORMATION REQUIRED.
  
 4) SHEET A-0.0 CODE SUMMARY INDICATES
 THE PLANS WERE DESIGNED TO THE 2001
 FBC. ALL REFRENCES TO CODE SECTIONS ALSO
 REFLECT THE DESIGN TO THE 2001FBC.
 OCT. 1, 2005 ALL PERMIT APPLICATIONS SUBMITTED
 ON THIS OR AFTER ARE TO BE DESIGNED TO THE
 2004 FBC, BUILDING & 2004 EXISTING BUILDING CODE.
 PLEASE CORRECT DESIGN TO THE 2004 FBC AND ALL CODE
 REFRENCES ARE TO REFLECT THE 2004 FBC.
  
 5) 2004 EXISTING BUILDING CODE PLEASE PROVIDE TO WHAT
 LEVEL
 OF ALTERATIONS WILL BE COMPLETED UNDER THIS PERMIT?
  
 6A)SHEET A8.1 SPECIFICATIONS INDICATE THIS DESIGN
 UNDER
 THE 2001 FBC, PLEASE CORRECT TO THE 2004 FBCAND THE
 WRONG ADDITION OF ASCESHOULD READ ASCE 7-02.
  
 6B) THE BUILDING CATEGORY LISTED AS I, THIS WOULD BE
 FOR
 FARM OUT BUILDINGS SMALL SHEDS.
  
 6C) PREMANUFACTUREDA/C STANDS REQUIRE, (2) COPIES:
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 PRODUCTS WILL REQUIRE FLORIDA COVERSHEET AND ASSOCIATED
 REPORT.
  
 6D))W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 7) PLANS DO NOT PROVIDE A SEATING ARANGEMENT FOR
 ACCESSIBILITY.
 PLEASE SHOW COMPLIANCE AND FOR11-5.2 COUNTERS AND
 BARS.
 WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34
  
 INCHES (865 MM) IN HEIGHT FOR CONSUMPTION BY CUSTOMERS
 SEATED
 ON STOOLS OR STANDING AT THE COUNTER, A PORTION OF THE
 MAIN COUNTER
 WHICH IS 60 INCHES (1525 MM) IN LENGTH MINIMUM SHALL BE
 PROVIDED
 IN COMPLIANCE WITH SECTION 11-4.32 OR SERVICE SHALL BE
 AVAILABLE AT
 ACCESSIBLE TABLES WITHIN THE SAME AREA.
  
 8) CHANGE OF OCCUPANCY WILL REQUIRE IMPACT FESS REVIEW:
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  


Account Summary | Usage Policy | Privacy Policy