| Date |
Text |
| 2006-11-17 15:14:32 | BUILDING PLAN REVIEW |
| | PERMIT: 06100214 |
| | ADD: 3654 GEORGIA AVE. |
| | CONT: INDUSTRIAL COMMERCIAL STRUCTURES |
| | TEL: (407)9484395 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2 )FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 3) PLEASE PROVIDE A SITE PLAN PROVIDING THISTENANT |
| | LOCATION WITHIN THE BUILDING. |
| | 106.1.2* ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 4) SHEET A-0.0 CODE SUMMARY INDICATES |
| | THE PLANS WERE DESIGNED TO THE 2001 |
| | FBC. ALL REFRENCES TO CODE SECTIONS ALSO |
| | REFLECT THE DESIGN TO THE 2001FBC. |
| | OCT. 1, 2005 ALL PERMIT APPLICATIONS SUBMITTED |
| | ON THIS OR AFTER ARE TO BE DESIGNED TO THE |
| | 2004 FBC, BUILDING & 2004 EXISTING BUILDING CODE. |
| | PLEASE CORRECT DESIGN TO THE 2004 FBC AND ALL CODE |
| | REFRENCES ARE TO REFLECT THE 2004 FBC. |
| | |
| | 5) 2004 EXISTING BUILDING CODE PLEASE PROVIDE TO WHAT |
| | LEVEL |
| | OF ALTERATIONS WILL BE COMPLETED UNDER THIS PERMIT? |
| | |
| | 6A)SHEET A8.1 SPECIFICATIONS INDICATE THIS DESIGN |
| | UNDER |
| | THE 2001 FBC, PLEASE CORRECT TO THE 2004 FBCAND THE |
| | WRONG ADDITION OF ASCESHOULD READ ASCE 7-02. |
| | |
| | 6B) THE BUILDING CATEGORY LISTED AS I, THIS WOULD BE |
| | FOR |
| | FARM OUT BUILDINGS SMALL SHEDS. |
| | |
| | 6C) PREMANUFACTUREDA/C STANDS REQUIRE, (2) COPIES: |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. |
| | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | PRODUCTS WILL REQUIRE FLORIDA COVERSHEET AND ASSOCIATED |
| | REPORT. |
| | |
| | 6D))W P B ADMINISTRTIVE CODE 106.3.3* |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 7) PLANS DO NOT PROVIDE A SEATING ARANGEMENT FOR |
| | ACCESSIBILITY. |
| | PLEASE SHOW COMPLIANCE AND FOR11-5.2 COUNTERS AND |
| | BARS. |
| | WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34 |
| | |
| | INCHES (865 MM) IN HEIGHT FOR CONSUMPTION BY CUSTOMERS |
| | SEATED |
| | ON STOOLS OR STANDING AT THE COUNTER, A PORTION OF THE |
| | MAIN COUNTER |
| | WHICH IS 60 INCHES (1525 MM) IN LENGTH MINIMUM SHALL BE |
| | PROVIDED |
| | IN COMPLIANCE WITH SECTION 11-4.32 OR SERVICE SHALL BE |
| | AVAILABLE AT |
| | ACCESSIBLE TABLES WITHIN THE SAME AREA. |
| | |
| | 8) CHANGE OF OCCUPANCY WILL REQUIRE IMPACT FESS REVIEW: |
| | BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |