| 2007-03-02 16:24:12 | BUILDING REVIEW FOURTH CHECKLIST: | | | 1- INFORMATION REQUESTED ON THIRD CHECKLIST REGARDING | | | THE FLAT ROOF WAS NOT PROVIDED: | | | NEED TO PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING | | | AT PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | | LIMITATION #7 ON PAGE 32 OF NOA 03-0501.02 SUBMITTED. | | | SELECTED ROOF ASSEMBLY ON PAGE 28 IS LIMITED BY GENERAL | | | LIMITATION #7 AND THE MAXIMUM DESIGN PRESSURES ARE | | | -45PSF.NEED TO PROVIDE THE RAS 117 CALCULATIONS | | | BECAUSE ACCORDING TO TABLE R301.2(2) OF 2004 FLORIDA | | | RESIDENTIAL CODE THE ROOF ASSEMBLY MUST MEET HIGHER | | | DESIGN PRESSURES AT PERIMETER AND CORNER AREAS. | | | | | | ***NOTE; | | | THERE WAS ACONTRACTOR'SAFFIDAVIT FORM SUBMITTED. | | | THIS AFFIDAVIT HAS NOTHING TO DO WITH RAS 117 | | | CALCULATIONS AND APPLIES TO PALM BEACH COUNTY BUILDING | | | DEPARTMENT ONLY,NOT CITY OF WEST PALM BEACH. IN | | | ADDITIONIT'S INCOMPLETE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|