| 2007-01-31 17:25:57 | PERMIT: 06100149 |
| | ADD: 512 SPENCER DRIVE |
| | CONT: HUNTER CONSTRUCTION |
| | TEL: (561)239-8351 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2NDREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) PROVISO: COMMENT # 5 FROM THE PREVIOUS REVIEW:THE |
| | COVERED PORTE COCHERE IS NOT PART OF THIS PERMIT BUT |
| | PLEASE PROVIDE |
| | THE CLEAR HEIGHT UNDER THE CANOPY TO COMPLY WITH: |
| | 11-4.6.5 VERTICAL CLEARANCES. |
| | PROVIDE MINIMUM VERTICAL CLEARENCE OF |
| | 114 INCHES AT ACCESSIBLE PASSENGER LOADING ZONES. |
| | |
| | 3) 2ND REQUEST COMMENT # 6 FROM THE PREVIOUS REVIEW, |
| | THE COVERED PORTECOCHERE IS NOT PART OF THIS PERMIT |
| | BUT |
| | PLEASE TAKE NOTE |
| | OF DETAIL B/ A-6. THE SIDE WALKIS 5'-3" WIDE AND THE |
| | COLUMNS ARE NOT |
| | DIMENSIONED FOR THE PORTE COCHERE BUT SCALE OUT TO BE |
| | 2'-0" WIDE |
| | LEAVING ONLY 3'-3" OF SIDEWALK 44" IS THE MINIMUM FOR A |
| | MEANS OF AN |
| | ACCISSIBLE ROUTE AND MEANS OF EGRESS . |
| | SHEET C-1 SECTION A-A INDICATES THE SIDEWALK TO BE A |
| | 5'-0" WIDE SIDEWALK, |
| | IF THE COLUMNOF THE PORT COCHERE IS 2'-0" WIDE THE |
| | REMAINING SIDEWALK WILL BE LESS |
| | THAN THE 44" WIDE FOR AN ACCESSIBLE MEANS OF EGRESS. |
| | |
| | 4 ) 2ND REQUEST, COMMENT # 7 FROM THE PREVIOUS REVIEW, |
| | THE RESPONSE INDICATED SEE C-2, THERE IS A |
| | SECTION THROUGH "G-G" THERE IS NO RAMP NOR HANDRAIL |
| | DEPICTED? |
| | SHEET A-4 INDICATES ON THE WEST SIDE OF THE EXISTING |
| | ALUMNI BLDG. |
| | DISABLED PARKING SPACES WITH A NEW ACCESS AISLE, |
| | LEADING TO WHAT |
| | APPEARS TO BETHE ENTRANCE OF THE BUILDING WITH |
| | STAIRS, BUT NO RAMP. |
| | ACCESSIBLE PARKING SPACESSERVING A PARTICULAR |
| | BUILDING SHALL BE |
| | LOCATED ON THE SHORTEST SAFELY ACCESSIBLE ROUTE OF |
| | TRAVEL FROM |
| | ADJACENT PARKING TO AN ACCESSIBLE ROUTE. |
| | |
| | 5) PROVISO: COMMENT # 10 FROM THE PREVIOUS REVIEW: |
| | SHEET A-6 THE PLANS INDICATE A CHANGE OF GRADE OF |
| | 1/2" |
| | OUT OF A 2 STORY CBS ADDITION, |
| | 11-4.5.2 CHANGES IN LEVEL. |
| | CHANGES IN LEVEL UP TO ? INCHES (6 MM) MAY BE VERTICAL |
| | AND WITHOUT |
| | EDGE TREATMENT [SEE FIGURE 11-7 (C)]. CHANGES IN LEVEL |
| | BETWEEN ? INCH |
| | AND ? INCH (6 MM AND 13 MM) SHALL BE BEVELED WITH A |
| | SLOPE NO GREATER |
| | THAN 1:2 [SEE FIGURE 11-7 (D)]. CHANGES IN LEVEL |
| | GREATER THAN ? INCH (13 MM) |
| | SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES |
| | WITH |
| | SECTION 11-4.7 OR 11-4.8 . |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |