Plan Review Notes
Plan Review Notes For Permit 06100105
Permit Number 06100105
Review Stop G
Sequence Number 2
Notes
Date Text
2006-11-29 11:50:30REVISION: CHANGE DRYER TO A "FUTURE" DRYER
  
 ************PROVISO************
 IF FUTURE DRYER ROOM IS A CONFINED SPACE, OPENINGS
 REQUIRED PER SECTION 304.5 OR
 SECTION 304.6 SHALL BE INSTALLED.
 MINIMUM 1,100 CUBIC FEET REQUIRED.
  
 IF WATER HEATER ROOM IS A CONFINED
 SPACE, OPENINGS REQUIRED PER SECTION
 304.5 OR SECTION 304.6 SHALL BE
 INSTALLED.
 MINIMUM 2,000 CUBIC FEET REQUIRED.
  
 FUTURE DRYER TO HAVE SHUT OFF VALVE INSTALLED AND TO BE
 CAPPED GAS TIGHT PER FBC-2004 FUEL GAS, SECTION 404.12.