2008-04-01 16:48:54DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
  
 1. A MINIMUM 2 COPIES OF ALL SHEETS TO BE REVISED SHALL
 BE SUBMITTED FOR REVIEW PER SECTION 106.1. ONLY ONE SET
 SUBMITTED.
  
 2. SHTS A-2, 2 0F 3 & A-3, 3 OF 3 STILL SHOW THE BREAK
 ROOM SINK AND SHT A-3 STILL SHOWS THE BREAK ROOM SINK
 DETAILS. PLEASE REVISE ALL SHEETS WITH THE BREAK ROOM
 SINK SHOWN. DELETE THE SINK REFERENCES TO REFLECT
 REVISION. SECTION 106.1.3.
  
 3. SHT P1 PLUMBING RISER BREAK AREA DOES NOT MEET CODE
 REQUIREMENTS. AS SHOWN THERE IS NO TRAP FOR THE ICE
 MAKER, AND THE ICE MAKER SHALL BE INDIRECTLY CONNECTED
 TO THE SANITARYSYSTEM NOT DIRECT CONNECTION AS SHOWN.
 SECTIONS 802.1.1 & 1002.1. A FLOOR SINK OR HUB DRAIN IS
 REQUIRED. SECTIONS 802.3 & 802.3.2.
  
 4. SHT P1 WATER RISER DIAGRAM. A WATER HAMMER ARRESTOR
 IS REQIRED AT THE ICE MACHINE PER SECTION 604.9. PLEASE
 INDICATE ON THE WATER RISER DIAGRAM. THE WATER HAMMER
 ARRESTOR SHALL BE LOCATED NEAR THE FIXTURE IN AN
 "EFFECTIVE RANGE", NOT IN THE CEILING. PDI-WH 201.
  
 5. ALL SHEETS. THE ADDRESS FOR THE ARCHITECT DOES NOT
 RELFECT THE ADDRESS OF RECORD ON THE FLORIDA STATE DBPR
 WEBSITE. (SEE ATTACHED SHEET). PLEASE UPDATE THE DBPR
 WEBSITE OR THE TITLE BLOCKS SO THEY CORRELATE. FAC
 61G1-16.004(1) & FS 481.2055.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  
  