| 2006-10-11 18:19:43 | BUILDING REVIEW CHECKLIST (PLAN REVIEW ONLY): |
| | |
| | 1- WHEN APPLYING FOR PERMIT WILL NEED: |
| | A) RECORDED NOTICE OF COMMENCEMENT. |
| | B) IMPACT FEES PAID TO PALM BEACH COUNTY. NEED COPY |
| | OF PAID RECEIPT AND STAMPED PLANS. |
| | C) PAY PERMIT FEES ACCORDINGLY. |
| | |
| | 2- NEED ENERGY CALCULATIONS AS REQUIRED BY CHAPTER 13 |
| | FBC 2004. |
| | |
| | 3- BOTH COPIES OF SURVEYS NEED TO HAVE ORIGINAL SEAL, |
| | SIGNATURE AND DATE AS REQUIRED BY CHAPTER 472 FLORIDA |
| | STATUTES. |
| | |
| | 4- PROVIDE FLORIDA OR LOCAL PRODUCT APPROVAL AS |
| | REQUIRED BY DCA RULE 9B-72 FOR: |
| | A) SINGLE HUNG WINDOWS. |
| | B) FIXED WINDOWS. |
| | C) ENTRY DOOR ASSEMBLY AS SHOWN ON PLANS AND |
| | ELEVATIONS. |
| | D) GARAGE DOOR. |
| | E) SLIDING GLASS DOORS. |
| | F) ALL SIMPSON AND USP CONNECTORS SPECIFIED ON PLANS |
| | AND DETAILS. |
| | G) PRECAST LINTELS. |
| | H) ROOF SHINGLES. |
| | |
| | 5- ARCHITECT TO REVIEW AND APPROVE IN WRITTING ALL |
| | PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY |
| | AMENDMENTS TO FBC 2004. INCLUDING THE STORM SHUTTERS. |
| | |
| | 6-A) ARCHITECT TO PROVIDE ORIGINAL SIGNATURE IN ALL |
| | DRAWINGS AS REQUIRED BY CHAPTER 481 FLORIDA STATUTES |
| | AND CLARIFY WHY THERE ARE DRAWINGS WITH DIFFERENT |
| | SIGNATURES. |
| | B) ARCHITECT TO PROVIDE ALL INFORMATION REQUIRED BY |
| | FAC SEC. 61G1-16.004 IN THE TITLE BLOCK. SEE ATTACHED |
| | COPY. |
| | |
| | 7- SURVEY AND ARCHITECT'S PLANS DON'T MATCH. REVISE AS |
| | REQUIRED. |
| | |
| | 8- SPECIFY SAFETY GLASS FOR WINDOW NEXT TO ENTRY DOOR |
| | AND BY THE BATHROOM BATHTUB AS REQUIRED BY SEC. R308.4 |
| | OF 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 9-REVISE SPECIFICATIONS FOR GARAGE DOOR LEADING TO |
| | THE INSIDE OF THE HOUSE. NEEDTO COMPLY WITH SEC. |
| | R309.1 2004 FLORIDA RESIDENTIAL CODE. |
| | |
| | 10- SPECIFY SIZE OF WINDOW FOR MASTER BEDROOM. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 11- PROVIDE SOIL TEST REPORT. |
| | |
| | 12-REVISE SITE PLAN.PROVIDE DRAINAGE PLAN SHOWING |
| | HOW IS WATER DIVERTED AWAY FROM THE STRUCTURE AND NO |
| | LEADING TO NEIGHBORS'S PROPERTY. SEC. R401.3 2004 |
| | FLORIDA RESIDENTIAL CODE. |
| | |
| | 13- SPECIFY ACTUAL SIZE OF ENTRY DOOR. NEED TO VERIFY |
| | COMPLIANCE WITH SEC. R311.4.2 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | |
| | 14- PROVIDE GARAGE DOOR STRUCTURAL BUCK DETAIL. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 15- CLARIFY SPECIFICATIONS FOR GABLE END SHEATHING. |
| | SPECS SHOWN ON ELEVATIONS (SHEET A-3) DON'T MATCH SPECS |
| | SHOWN ON GABLE END SECTION (SHEET S-2). REVISE AS |
| | REQUIRED. |
| | |
| | 16- SHEET A-3: |
| | A) PROVIDE CALCULATIONS SHOWING HOW THE DESIGN |
| | PRESSURES WERE DETERMINED. SEC. 106.1.2 CITY AMENDMENTS |
| | TO FBC 2004.PRESSURES ARE LOWER THAN THOSE SHOWN IN |
| | ASCE-02 TABLES. |
| | B) ROOF LOADS DON'T MATCH ROOF LOADS SHOWN ON SHEET |
| | S-2. REVISE AS REQUIRED. |
| | |
| | 17-SHEET S-1: UPDATE ALL STRUCTURAL GENERAL NOTES. |
| | SEE 2004 FLORIDA RESIDENTIAL CODE AND 2004 FLORIDA |
| | BUILDING CODE FOR CORRECT REFERENCE STANDARDS USED AND |
| | SPECIFIC EDITIONS. |
| | |
| | 18- SHEET S-2: |
| | A) GABLE END SECTION DETAIL:(1) REVISE CONNECTOR |
| | USP RT24F. NEED TO SPECIFY MASONRY CONNECTOR. SEE |
| | CATALOGUE FOR PROPER CONNECTORS. |
| | (2)SPECIFY SILL PLATE FOR 2X6 STUDS AND SPECIFY |
| | HOW IS IT FASTENED. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| | 2004. |
| | B) REVISE ROOF LOADS TO INCLUDE THE ATTIC LOADS AS |
| | REQUIRED BY TABLE R301.5 2004 FLORIDA RESIDENTIAL |
| | CODE. |
| | C) NAILING ZONE PLAN IS MISSING ZONE #3. SEE FIGURE |
| | R301.1.2(8) 2004 FLORIDA RESIDENTIAL CODE. |
| | D) NAILING ZONE PLAN DOESN'T PROVIDE ANY SPECS FOR |
| | SHEATHING FASTENING. SPECIFY. |
| | E) CLARIFY IF USING TWO BOND BEAMS OR ONE. BEAM |
| | SCHEDULE CALLS FOR ONE, WHILE TYP. WALL SECTION SHOWS |
| | TWO.CLARIFY. |
| | F) CONNECTION SCHEDULE: SEE CURRENT USP AND SIMPSON |
| | CATALOGUES AND REVISE NUMBER AND SIZE OF NAILS USED. |
| | OTHERWISE, COMPLETE ENGINEERING ANALYSIS IS REQUIRED |
| | FOR NAIL SIZE AND NUMBER THAT DIFFER FROM THE ONE |
| | TESTED AND PUBLISHED BY THE MANUFACTURER.SEC. 106.1.2 |
| | CITY AMENDMENTS TO FBC 2004. |
| | G) SIZE OF SOFFIT VENTS DOESN'T MATCH SIZE SHOWN ON |
| | TYP. WALL SECTION. REVISE AS REQUIRED. |
| | H) SPECIFY TRUSS CONNECTORS AT THE END OF TRUSS |
| | GIRDERS BY THE ENTRY AREA. SEE COMMENTS ON PLANS. |
| | I) SPECIFY TRUSS CONNECTORS FOR TRUSSES THAT ARE |
| | RESTING ON THE DOUBLE PT LEDGER BY ENTRY AREA. |
| | |
| | 19- TRUSS DRAWINGS WILL BE REQUIRED PRIOR TO |
| | INSTALLATION AS REQUIRED BY SEC. R802.10. 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 20- NEED TO PROVIDE BATHROOM WITH DOOR THAT ALLOWS MIN. |
| | 29" CLEAR OPENING AS REQUIRED BY SEC. R22 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 21- IF NOT USING DOOR AND WINDOWS WITH IMPACT GLAZING, |
| | THEN NEED TO PROVIDE COMPLETE INFORMATION FOR SHUTTERS. |
| | NEED PRODUCT APPROVAL, KEY PLAN AND A COMPLETE |
| | INSTALLATION SCHEDULE. SEE ATTACHED SAMPLE OF |
| | INSTALLATION SCHEDULE. |
| | |
| | JULIO GOMEZ |