| Plan Review Notes For Permit 06090903 |
| Permit Number |
06090903 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2007-02-14 12:43:44 | DENIED BY BUILDING | | | | | | 1) THE NOC THAT WAS SUBMITTED HAS EXPIRED. IT WILL NEED | | | TO BE RERECORDED. | | | | | | 2) THE LIFE SAFETY SUMMARY ON 12.1 INCORRECTLY | | | SPECIFIES THAT ONLY ONE EXIT IS REQUIRED. WITH AN | | | OCCUPANT LOAD OF MORE THAN 50 AND/OR THE COMMON PATH OF | | | TRAVEL MORE THAN 100' IF ONLY ONE EXIT, FBC 1014.1 | | | REQUIRES TWO EXITS. PLEASE CORRECT. | | | | | | 3) ADDRESS COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|