| 2007-09-24 07:52:35 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC |
| | FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | PROVISO ITEMS |
| | REVISION DATED 8/21/07 |
| | |
| | |
| | 1.)SUBMIT PRODUCT APPROVALS COMPLIANT WITH THE DESIGN |
| | PRESSURE REQUIREMENT OF +-33 (S2.1) FOR THE GARAGE |
| | DOORS OR REVISE S2.1.THE PRODUCT APPROVAL SUBMITTED |
| | HAS DP LIMITATION OF +28/-32. |
| | |
| | A FLORIDA STATE PRODUCT APPROVAL WAS SUBMITTED WITH |
| | SHOP DRAWINGS WHICH DO NOT SHOW ANY DESIGN PRESSURES. |
| | PRINT THE DOCUMENTS FROM THE WEBSITE; EVALUATION REPORT |
| | (WHICH SHOULD HAVE THE DESIGN PRESSURES FOR THIS |
| | PRODUCT) AND INSTALLATION INSTRUCTIONS.HAVE THE |
| | PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD PRIOR |
| | TO SUBMITTAL, FBC*106.3.3. |
| | |
| | 2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| | FOR THE ROOF HATCH FAC9B72. |
| | |
| | SHOP DRAWINGS WERE SUBMITTED.PROVIDE FLORIDA STATE |
| | PRODUCT APPROVAL OR APPLY FOR LOCAL PRODUCT APPROVAL AS |
| | REQUIRED BY FAC9B72. |
| | |
| | 3.)THE ROOFING PRODUCT APPROVALS WERE ALREADY |
| | SUBMITTED.HOWEVER, SEE GENERAL LIMITATION #7. |
| | ENHANCED FASTENING CALCULATIONS PREPARED BY AN |
| | ARCHITECT, ENGINEER, OR REGISTERED ROOF CONSULTANT |
| | REQUIRED.(OK -SUBMITTED W/ROOF PERMIT 07070582) |
| | |
| | (NOA06-0626.05, ASSEMBLY PAGE 27) |