| Date |
Text |
| 2006-10-16 08:40:37 | DENIED |
| | |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE |
| | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY |
| | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF |
| | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT |
| | COMMENCED WITHIN 90 DAYS OF RECORDING. |
| | |
| | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.PLANS SUBMITTED AFTER OCTOBER 1, 2005 SHALL BE |
| | DESIGNED TO THE 2004 FBC AND2004 FLORIDA RESIDENTIAL |
| | CODE AND 2004 EXISTING BUILDING CODE.CORRECT CODE |
| | SECTIONS SHOWN.SEE ALSO ASCE 7-98 SHOULD BE ASCE 7-02 |
| | , STRUCTURAL NOTE 2C. |
| | |
| | 4.WINDOW AT TUB LOCATONS SHALL HAVE SAFTEY GLAZING. |
| | R 308.4 |
| | |
| | 5.PROTECTION AGAINST DECAY.R 319.1IN AREAS |
| | SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY TABLE |
| | R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE THE |
| | USE OF AN APPROVED SPECIES AND GRADE OF LUMBER, |
| | PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3, |
| | C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2 |
| | AND P3, OR DECAY-RESISTANT HEARTWOOD OF REDWOOD, BLACK |
| | LOCUST, OR CEDARS. |
| | 2.ALL WOOD FRAMING MEMBERS THAT REST ON |
| | CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE |
| | LESS THAN 8 INCHES FROM THE EXPOSED GROUND. |
| | 5.WOOD SIDING, SHEATHING AND WALL |
| | FRAMING ON THE EXTERIOR OF A BUILDING HAVING A |
| | CLEARANCE OF LESS THAN 6 INCHESFROM THE GROUND. |
| | |
| | 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY |
| | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL |
| | ATTACHED.NOTE:INCORRECT STATE PAGES SUBMITTED FOR |
| | PGT, TAMKO AND TOWN AND COUNTRY.SEE TM WINDOW AND |
| | DOOR APPROVAL FOR AN EXAMPLE. |
| | |
| | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF |
| | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN |
| | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC |
| | FORM PER RULE 9B-72. SEE ATTACHMENT. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. |
| | |
| | |
| | 8.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR |
| | A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS |
| | WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC |
| | EXISTING BUILDING 301.5 |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE |
| | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET |
| | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | CONSTRUCTION SERVICES DEPARTMENT |
| | 561-805-6672 |
| | |
| | |
| | |
| | |