| Plan Review Notes For Permit 06090625 |
| Permit Number |
06090625 |
|
| Review Stop |
Z |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2007-06-11 15:48:54 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. HANDICAP ACCESS AISLE SHALL NOT ENCROACH INTO THE | | | REQUIRED 12 FOOT DRIVE AISLE. | | | | | | 2. HANDICAP ACCESS AISLE SHALL BE STRIPED DIAGONALLY TO | | | DESIGNATE IT AS A NO-PARKING ZONE. | | | | | | 3. HANDICAP ACCESS AISLE SHALL BE 5 FEET MIN IN WIDTH | | | BY THE ENTIRE LENGTH OF THE PARKING SPACE (18 FEET). | | | | | | 4. REMOVE NOTE DESIGNATING PARKING AS EMPLOYEE PARKING | | | SPACES. | | | | | | 5. PROVIDE A LETTER AND PLANS STAMPED APPROVED FROM THE | | | ENGINEERING SERVICES DEPARTMENT FOR THE SIZE AND | | | LOCATION OF THE DUMPSTER AND DUMPSTER ENCLOSURE. | | | | | | 6. FDOT APPROVAL LETTER FOR THE METAL AWNINGS/CANOPIES | | | SHALL BE PROVIDED PRIOR TO BUILDING PERMIT APPROVAL. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|