| Date |
Text |
| 2007-03-20 12:50:29 | PLANNING AND ZONING DEPARTMENT |
| | |
| | ***FAILED*** |
| | |
| | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. |
| | |
| | 2. ALL ARCHITECTURAL DRAWINGS SHALL REFLECT THE EXACT |
| | LOCATION OF THE WEST PROPERTY LINE.ACCORDING TO THE |
| | SURVEY AND SITE PLAN, THE WEST PROPERTY LINE RUNS EAST |
| | OF THE SIDEWALK ALONG SPRUCE AVENUE; HOWEVER, THE |
| | ARCHITECTURAL DRAWINGS SHOW THE PROPERTY LINE WEST OF |
| | THE SIDEWALK ALONG SPRUCE AVENUE. |
| | |
| | 3. ACCORDING TO THE SITE PLAN AND ARCHITECTURAL |
| | DRAWINGS, ONLY THE PROPOSED COFFEE SHOP IS NOT PART OF |
| | THIS PERMIT APPLICATION.HOWEVER, ALL ENGINEERING |
| | PLANS (PLUMBING, MECHANICAL, AND ELECTRICAL), SHOW THAT |
| | THE ENTIRE WEST PORTION OF THE SITE IS NOT PART OF THIS |
| | PERMIT APPLICATION.FURTHERMORE, THE SITE PLAN, |
| | ARCHITECTURAL DRAWINGS AND SOME OF THE ENGINEERING |
| | PLANS SHOW THE JANITOR CLOSET/VENDING MACHINE AREA AS |
| | PART OF THIS PERMIT APPLICATION, BUT OTHER ENGINEERING |
| | PLANS STATE THAT IT IS NOT PART OF THIS CONTRACT.ALL |
| | PLANS AND DRAWINGS SHALL REFLECT THE SAME CONDITIONS. |
| | PLEASE CLARIFY WHAT IS AND WHAT IS NOT INCLUDED IN THIS |
| | PERMIT APPLICATION. |
| | A. PLEASE NOTE THAT IF ONLY THE PROPOSED COFFEE SHOP IS |
| | TO BE EXCLUDED, A SITE PLAN AND LANDSCAPE PLAN SHALL BE |
| | PROVIDED FOR THE WEST PORTION OF THE SITE. |
| | B. PLEASE NOTE THAT PER SECTION 94-210(D)(11), |
| | AUTOMATIC FOOD AND DRINK MACHINES MUST BE LOCATED |
| | INSIDE BUILDINGS.IF THE VENDING MACHINE AREA WILL BE |
| | ENCLOSED, THE AREA SHALL BE TWO STORIES PER NMUD |
| | REGULATIONS. |
| | C. PROPOSED JANITOR CLOSET SHALL BE TWO STORIES. |
| | |
| | 4. LANDSCAPE PLANS, PREPARED BY A LANDSCAPE |
| | ARCHITECT AND AUTHORIZED BY F.S. CH. 481, PT. II, SHALL |
| | BE PROVIDED. |
| | |
| | 5. FDOT APPROVAL FOR THE PROPOSED METAL AWNINGS ON THE |
| | WINDOWS SHALL BE PROVIDED. |
| | |
| | 6. ACCESSIBLE ROUTES FOR HANDICAP PARKING SPACES SHALL |
| | BE NO LESS THAN 44 INCHES WIDE. |
| | |
| | 7. PROVIDE HANDICAP PARKING STALL DETAIL. |
| | A. PARKING ACCESS AISLES FOR HANDICAP PARKING SPACES |
| | MUST BE NO LESS THAN 5 FEET WIDE. |
| | B. HANDICAP PARKING SPACES MUST BE PROMINENTLY OUTLINED |
| | IN BLUE PAINT. |
| | C. HANDICAP SYMBOL MUST BE FACING RIGHT (OPPOSITE |
| | DIRECTION) |
| | D. HANDICAP SYMBOL SHALL BE 3 FEET OR 5 FEET HIGH AND |
| | WHITE IN COLOR. |
| | E. HANDICAP SYMBOL SHALL BE 2 FEET FROM THE OPEN END OF |
| | THE PARKING SPACE. |
| | |
| | 8. PER THE FINAL ORDER DATED FEBRUARY 1, 2007, THE TWO |
| | NEW WINDOWS SHALL 2 FEET ABOVE THE GROUND.ACCORDING |
| | TO THE ELEVATIONS SUBMITTED, THE WINDOWS ARE 2 FEET 6 |
| | INCHES ABOVE THE GROUND.THESE WINDOWS SHALL BE |
| | RECONFIGURED TO MEET THIS CONDITION OF THE FINAL |
| | ORDER. |
| | |
| | 9. EXTERIOR FINISH MATERIAL OF THE PROPOSED TICKET |
| | BOOTH SHALL BE PROVIDED.PLEASE NOTE THAT PER SECTION |
| | 94-213(D)(1), WALLS SHALL BE NO MORE THAN TWO MATERIALS |
| | AND SHALL CHANGE MATERIAL ALONG A HORIZONTAL LINE, WITH |
| | THE HEAVIER MATERIAL BELOW THE LIGHTER MATERIAL. |
| | |
| | 10. TOTAL CLEAR GLAZED AND OPENINGS PERCENTAGE SHALL BE |
| | PROVIDED FOR THE SECOND STORY.PLEASE NOTE THAT PER |
| | SECTION 94-213(D)(6), STORIES ABOVE THE FIRST FLOOR |
| | SHALL HAVE CLEAR GLAZED ARE AND OPENINGS BETWEEN 25 |
| | PERCENT AND 45 PERCENT OF THE FACADE AREA. |
| | |
| | 11. PER SECTION 94-213(D)(7), WINDOWS SHALL BE RECESSED |
| | A MINIMUM OF TWO INCHES FROM THE EXTERIOR FACE OF THE |
| | FACADE. |
| | |
| | 12. PER SECTION 94-213(D)(13), ALL WINDOWS, EXCEPT |
| | STOREFRONT WINDOWS, SHALL BE OPERABLE. |
| | |
| | 13. PLEASE NOTE THAT A SIGN PERMIT SHALL BE SUBMITTED |
| | FOR ALL NEW SIGNS. |
| | |
| | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC |
| | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |