| 2007-07-17 20:44:28 | BUILDING PLAN REVIEW |
| | PERMIT: 06090366 |
| | ADD: 221 CLEMATIS ST SUITE 201 & 202 |
| | CONT: CASTLE FLORIDA |
| | TEL: (561)856-6655 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RDREVIEW |
| | ACTION: DENIED |
| | |
| | --- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS |
| | NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 2) COMPLIED. |
| | |
| | 3A)3RD REQUEST, PLANS INDICAE A CODE SUMMARY A TYPE |
| | II-BBUILDING SPRINKLERED AND A ASSEMBLY GROUP A-2. |
| | TABLE 503 A-2 TYPE II-B ALLOWABLE AREA IS 9,500 SQ FT 2 |
| | STORIES. PLANS INDICATE THE FOOTPRINT OF THE BUILDING |
| | AS 21,213 SQ FT. |
| | PLEASE PROVIDE WHAT AREA AND OR HEIGHT INCREASES THAT |
| | YOU MAY TAKE, ALSO NOTE THIS ISCONSIDERED A (4) STORY |
| | BUILDING, THE |
| | 3RD AND 4TH FLOORS BEING PROPOSED A BUSINESS |
| | OCCUPANCY.TABLE 503, 504.2 AUTOMATIC SPRINKLER |
| | INCREASES. |
| | NEW COMMENT: YES THE SPRINKLER AND FRONTAGE INCREASES |
| | WILL PROVIDE THE AREA FOR A TYPE II-B BUILDING, THE |
| | **HEIGHT** INCREASE IS ONLY ONE ADDITIONAL STORY. THE |
| | DESIGN TEAM WILL NEED TO EVALUATE IF THE TYPE IIA WILL |
| | MAKE THE REQUIREMENTS OF TABLE 503FOR A FULLY |
| | SPRINKLERED BUILDING. NOTE THIS WILL MEAN THE TOTAL |
| | BUILDINGS COLUMNS TO BE 1 HR FIRE RATED, FLOOR |
| | ASSEMBLIES SEE TABLE 601. |
| | |
| | 3B)(1)COMPLIED. |
| | |
| | 3B)(2)COMPLIED, NOT GOING TO CHANGE THE EXTERIOR OF |
| | THE BUILDING. |
| | |
| | 3C)(1) COMPLIED, REMOVED FROM THIS PERMIT, UNDER |
| | SEPERATE PERMIT. |
| | PLEASE NOTE THERE IS NO MENTION OF THE EXITS AT |
| | THE REAR OF THE BUILDING ADJACENT TO THE ALLEY WAY. OUR |
| | JOBSITE MEETING (LAST |
| | WEEK OF DEC) REVEALED THE WEST EXIST STAIRS |
| | TO HAVE SEVERAL CODE VIOLATIONS: |
| | (1) THE EXIT DOOR TO THE STAIRWAY SWUNG INTO THE |
| | STAIRWELL, OCCUPANT LOAD > 50. |
| | (2) THERE APPEARED TO BE A KITHEN EXHAUST DUCK |
| | CUT INTO THE EXIT. |
| | (3) THERE ALSO WAS A VESTIBULE AREA DIRECTLY |
| | BEHIND THE STAIRWELL THE |
| | EXHAUST DUCK DUMPED INTO, THERE IS ANOTHER |
| | EXIT DOOR NOT DETERMINED |
| | WHERE IS AN EXIT FROM |
| | (4 THE STAIRWELL WAS NOT TRUELY FIRE RATED. (5) |
| | THERE WAS WINDOWS ON THE PROPERTY LINE. (6) AT |
| | THE TOP OF THE STAIRWAY NO DOOR OR ENCLOSURE. |
| | (7) IT APPEARS THAT THERE IS PLUMBING 6"OR 8" AT |
| | THE TOP OF THE LANDING |
| | (8) ALSO STAIRS TO THE MEZZANINE LEVEL ALSO HAD |
| | ISSUES WITH |
| | ELECTRICAL CONDUCTORS RUNNING THROUGH THE |
| | STAIRWELL. |
| | (9) THERE ALSO APPEARS TO BE HEIGTH PROBLEMS, |
| | MINIMUM HEADROOM |
| | (10) NO EXIT LIGTS OR DIRECTIONAL SIGNS |
| | |
| | 3C()2)COMPLIED, UNDER A SEPERATE PERMIT. |
| | THE STAIRWELL TO THE EAST END OF THE ASSEMBLY |
| | OCCUPANCY SUITE# 202ALSO HAD SEVERAL CODE VIOLATIONS |
| | : |
| | (1) STORAGE IN THE STAIRWELL |
| | (2) ELECTRIC PANELS AT EACH FLOOR LEVEL |
| | (3) NO APPROVED EXIT LIGHTING, OR DIRECTIONAL |
| | SIGNS |
| | (4) THE EXIT DOOR ALSO SWINGS OUT OVER THE |
| | PROPERTY LINE. |
| | (5) IT APPEARS THERE IS ALSO PLUMBING IN THE |
| | STAIRWELL. |
| | |
| | 4) WILL REFER BACK TO 3A) FOR ANSWER. |
| | |
| | 5) COMPLIED, REMOVED FROM SCOPE OF WORK. |
| | |
| | 6) COMPLIED. |
| | |
| | 7) COMPLIED. |
| | |
| | 8A)COMPLIED, REMOVED FROM SCOPE OF WORK. |
| | |
| | 8B)COMPLIED. REMOVED FROM THE SCOPE OF WORK. |
| | |
| | 8C)COMPLIED. REMOVED FROM THE SCOPE OF WORK. |
| | |
| | 8D) COMPLIED, REMOVEDFROM THE SCOPE OF WORK. |
| | |
| | 8E)COMPLIED, REMOVED FROM SCOPE OF WORK. |
| | |
| | 9) COMPLIED. |
| | |
| | 10) COMPLIED, REMOVED FROM THE SCOPE OF WORK. |
| | |
| | 11) COMPLIED. |
| | |
| | 12)COMPLIED. |
| | |
| | 13) COMPLIED. |
| | |
| | 14) COMPLIED. |
| | |
| | 15) COMPLIED. |
| | |
| | 16) COMPLIED. |
| | |
| | 17) COMPLIED. |
| | |
| | 18)COMPLIED. |
| | |
| | 19) COMPLIED, THE EAST EXIT IS IN A 2HR RATED SHAFT, |
| | 4STORY BUILDING . |
| | |
| | 20) COMPLIED. |
| | |
| | 21) COMPLIED. |
| | |
| | 22) COMPLIED. |
| | |
| | 23) COMPLIED. |
| | |
| | 24) COMPLIED. |
| | |
| | 25) COMPLIED. |
| | |
| | BUILDING PLAN REVIEW |