| Date |
Text |
| 2009-02-03 11:46:17 | BUILDING PLAN REVIEW |
| | PERMIT: 06090366 |
| | ADD: 221 CLEMATIS ST |
| | CONT: CASTLE FLORIDA |
| | TEL: (561)441-0492 MARK |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ * WEST PALM BEACH AMENDMENTS |
| | |
| | REVISION- DATED 1-21-09 |
| | ACTION: DENIED |
| | |
| | 1) SHEETS A1, A4 & A5 THE FRONT WINDOW/ FOLDING DOOR |
| | ASSEMBLY FOUND ON THE FRONT OF THE BUILDING 2ND FLOOR |
| | THE DESIGN PRESSURES AND PRODUCT APPROVALS DO NOT |
| | INDICATE THEY HAVE BEEN REVIEWED BY THE DESIGN TEAM. |
| | 106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC... |
| | |
| | 2) THE DETAILED WIND LOAD DESIGN WAS COMPLETED USING A |
| | MEAN ROOF HEIGTH OF 30 FEET WHERE AS THE BUILDING |
| | HEIGTH IS TAKEN FROM THE HEIGHTEST FLOOR FOR THE |
| | NEGATIVE VALUES. SHEET A-5INDICATES TTHE HIGHEST ROOF |
| | DECK TO BE 48'-7" WHICH WILL ENACT TABLE 1609.6.2.1(4) |
| | ADJUSTMENT FACTORS FOR BUILDING HEIGHTS B-ZONE 50'-0" |
| | 1.16 FACTOR PLEASE RE-RUN THE WIND CALCULATIONS AS PER |
| | TABLE 1609.6.2.1(4). |
| | |
| | 3) WIND DESIGN BY GLENN GOLDBERG PE COMPANY NAME |
| | VINTAGE DESGN & CONSTRUCTION, INC, 61G15-23.002(2) FL. |
| | ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL |
| | ENGINEER SHALL INCLUDE EITHER THE: NAME, ADDRESS AND |
| | LICENSE NUMBER OF THE ENGINEER OR, THE NAME AND LICENSE |
| | NUMBER OF THE ENGINEER AND THE NAME, ADDRESS AND |
| | CERTIFICATE OF AUTHORIZATION NUMBER OF THE ENGINEERING |
| | BUSINESS THROUGH WHICH THE ENGINEER IS PRACTICING |
| | (471.025 F.S. AND 471.023 F.S.). |
| | |
| | 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE |
| | BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER |
| | PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A |
| | PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL |
| | INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD |
| | THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND. |
| | |
| | 4) RCL STRUCTURAL ENGINEERING, LLC 61G15-23.002(2) FL. |
| | ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL |
| | ENGINEER SHALL INCLUDE EITHER THE: NAME, ADDRESS AND |
| | LICENSE NUMBER OF THE ENGINEER OR, THE NAME AND LICENSE |
| | NUMBER OF THE ENGINEER AND THE NAME, ADDRESS AND |
| | CERTIFICATE OF AUTHORIZATION NUMBER OF THE ENGINEERING |
| | BUSINESS THROUGH WHICH THE ENGINEER IS PRACTICING |
| | (471.025 F.S. AND 471.023 F.S.). |
| | |
| | 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE |
| | BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER |
| | PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A |
| | PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL |
| | INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD |
| | THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND. |
| | |
| | 5) RCL ENGINEERING IS USING THE MORE RESTRICTIVE "C" |
| | EXPOSURE BUT DOES NOT INDICATE THE MEAN ROOF HEIGTH OF |
| | THE BUILDING, TABLE 1609.6.2.1(4) PLEASE CORRECT THE |
| | ASSUMPTIONS AND DESIGN PRESSURES. |
| | |
| | 6) SHEET A-3 DETAIL4 &6 PLEASE PROVIDE THE CALCULATIONS |
| | FOR GUARDRAIL SYSTEM 1607.7.1.1.CONCENTRATED LOAD. |
| | HANDRAIL ASSEMBLIES AND GUARDS SHALL BE ABLE TO RESIST |
| | A SINGLE CONCENTRATED LOAD OF 200 POUNDS (0.89 KN), |
| | APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP, |
| | AND HAVE ATTACHMENT DEVICES AND SUPPORTING STRUCTURE TO |
| | TRANSFER THIS LOADING TO APPROPRIATE STRUCTURAL |
| | ELEMENTS OF THE BUILDING. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953. |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. UNDER FLORIDA STATE STATUTE SB 80, E-MAIL |
| | ADDRESSES ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO |
| | OR FROM LOCAL OFFICIALS REGARDING CITY BUSINESS ARE |
| | PUBLIC RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST. |
| | YOUR E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO |
| | PUBLIC DISCLOSURE. |
| | |
| | |