2009-02-03 11:46:17BUILDING PLAN REVIEW
 PERMIT: 06090366
 ADD: 221 CLEMATIS ST
 CONT: CASTLE FLORIDA
 TEL: (561)441-0492 MARK
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ * WEST PALM BEACH AMENDMENTS
  
 REVISION- DATED 1-21-09
 ACTION: DENIED
  
 1) SHEETS A1, A4 & A5 THE FRONT WINDOW/ FOLDING DOOR
 ASSEMBLY FOUND ON THE FRONT OF THE BUILDING 2ND FLOOR
 THE DESIGN PRESSURES AND PRODUCT APPROVALS DO NOT
 INDICATE THEY HAVE BEEN REVIEWED BY THE DESIGN TEAM.
 106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
  
 2) THE DETAILED WIND LOAD DESIGN WAS COMPLETED USING A
 MEAN ROOF HEIGTH OF 30 FEET WHERE AS THE BUILDING
 HEIGTH IS TAKEN FROM THE HEIGHTEST FLOOR FOR THE
 NEGATIVE VALUES. SHEET A-5INDICATES TTHE HIGHEST ROOF
 DECK TO BE 48'-7" WHICH WILL ENACT TABLE 1609.6.2.1(4)
 ADJUSTMENT FACTORS FOR BUILDING HEIGHTS B-ZONE 50'-0"
 1.16 FACTOR PLEASE RE-RUN THE WIND CALCULATIONS AS PER
 TABLE 1609.6.2.1(4).
  
 3) WIND DESIGN BY GLENN GOLDBERG PE COMPANY NAME
 VINTAGE DESGN & CONSTRUCTION, INC, 61G15-23.002(2) FL.
 ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE: NAME, ADDRESS AND
 LICENSE NUMBER OF THE ENGINEER OR, THE NAME AND LICENSE
 NUMBER OF THE ENGINEER AND THE NAME, ADDRESS AND
 CERTIFICATE OF AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS THROUGH WHICH THE ENGINEER IS PRACTICING
 (471.025 F.S. AND 471.023 F.S.).
  
 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE
 BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A
 PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL
 INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD
 THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND.
  
 4) RCL STRUCTURAL ENGINEERING, LLC 61G15-23.002(2) FL.
 ADMIN. CODE. PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE: NAME, ADDRESS AND
 LICENSE NUMBER OF THE ENGINEER OR, THE NAME AND LICENSE
 NUMBER OF THE ENGINEER AND THE NAME, ADDRESS AND
 CERTIFICATE OF AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS THROUGH WHICH THE ENGINEER IS PRACTICING
 (471.025 F.S. AND 471.023 F.S.).
  
 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE
 BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER
 PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A
 PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL
 INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD
 THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND.
  
 5) RCL ENGINEERING IS USING THE MORE RESTRICTIVE "C"
 EXPOSURE BUT DOES NOT INDICATE THE MEAN ROOF HEIGTH OF
 THE BUILDING, TABLE 1609.6.2.1(4) PLEASE CORRECT THE
 ASSUMPTIONS AND DESIGN PRESSURES.
  
 6) SHEET A-3 DETAIL4 &6 PLEASE PROVIDE THE CALCULATIONS
 FOR GUARDRAIL SYSTEM 1607.7.1.1.CONCENTRATED LOAD.
 HANDRAIL ASSEMBLIES AND GUARDS SHALL BE ABLE TO RESIST
 A SINGLE CONCENTRATED LOAD OF 200 POUNDS (0.89 KN),
 APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP,
 AND HAVE ATTACHMENT DEVICES AND SUPPORTING STRUCTURE TO
 TRANSFER THIS LOADING TO APPROPRIATE STRUCTURAL
 ELEMENTS OF THE BUILDING.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 MEMBER OF BOAF, THE BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA: PROTECTING LIVES AND PROPERTY SINCE 1953.
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. UNDER FLORIDA STATE STATUTE SB 80, E-MAIL
 ADDRESSES ARE PUBLIC RECORDS.WRITTEN COMMUNICATIONS TO
 OR FROM LOCAL OFFICIALS REGARDING CITY BUSINESS ARE
 PUBLIC RECORD, AVAILABLE TO THE PUBLIC UPON REQUEST.
 YOUR E-MAIL COMMUNICATIONS ARE THEREFORE SUBJECT TO
 PUBLIC DISCLOSURE.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved