| 2007-06-20 16:58:13 | DENIED BY BUILDING |
| | |
| | NOTE: THE ORIGINAL SCOPE OF WORK WAS CHANGED AND NEW |
| | DRAWINGS WERE SUBMITTED. |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT |
| | MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. THE WORK IS REQUIRED TO BEGIN |
| | WITHIN 90 DAYS OF THE DATE THE NOC IS RECORDED OR IT |
| | WILL HAVE TO BE RE-RECORDED. |
| | |
| | 2) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE |
| | SIGNED BY THE OWNER/AGENT. |
| | |
| | 3) PROVIDE A DRAINAGE PLAN FOR THE LOT AS REQUIRED BY |
| | FBC R401.3. INDICATE HOW AND WHERE THE SURFACE WATER |
| | WILL BE DIRECTED TO AN APPROVED POINT OF COLLECTION. |
| | |
| | 4) SPECIFY HOW THE ROOF VENTILATION AS REQUIRED BY FBC |
| | R806.1 WILL BE PROVIDED FOR THE FLAT ROOF ADDITION. |
| | |
| | 5)SHOW COMPLIANCE WITH R903.4 FOR ROOF DRAINAGE. |
| | INDICATE THE LOCATIONS AND SIZES OF THE ROOF DRAINS OR |
| | SCUPPERS. PROVIDE CALCULATIONS FOR SCUPPER SIZING. |
| | SPECIFY SIZES AND LOCATIONS OF OVERFLOW SCUPPERS AS |
| | REQUIRED BY R903.4.1. |
| | |
| | 6) SHOW COMPLIANCE WITH R320.7, WHICH REQUIRES ALL |
| | BUILDINGS WITH EAVES LESS THAN 6" TO HAVE GUTTERS WITH |
| | DOWNSPOUTS THAT DISCHARGE AT LEAST ONE FOOT FROM THE |
| | STRUCTURE. |
| | |
| | 7) FBC R905.3.3.1 FOR LOW SLOPE ROOFS REQUIRES TWO |
| | LAYERS OF UNDERLAYMENT. SPECIFY TWO LAYERS OF |
| | UNDERLAYMENT FOR THE 3:12 AND 2.25:12 PITCH ROOF. |
| | |
| | 8) PLEASE REVISE SCOPE OF WORK ON SHEET C1. THE SCOPE |
| | OF WORK WAS CHANGED TO ELIMINATE THE SECOND STORY. |
| | |
| | 9) PLEASE REVISE THE UPLIFT INFORMATION ON C1. THERE IS |
| | NO LONGER AN UPPER AND LOWER ROOF. THERE IS A SLOPED |
| | ROOF AND A FLAT ROOF. PLEASE REVISE THE SPECIFIED |
| | UPLIFT PRESSURES TO COMPLY WITH FBC TABLE 1609.6.2.1(2) |
| | OR SUBMIT SIGNED AND SEALED CALCULATIONS INDICATING HOW |
| | THE PRESSURES WERE DETERMINED. |
| | |
| | 10) THE LIST OF PRODUCT APPROVALS ON C1 SPECIFIES FLAT |
| | ROOF AND THIS SHOULD STATE FLAT ROOF COVERING MATERIAL |
| | OR BUR ROOF SYSTEM. PLEASE CORRECT. THE PRODUCT |
| | APPROVALS ARE REQUIRED TO BE SUBMITTED. THIS PRODUCT |
| | APPROVAL CONTAINS SEVERAL APPROVED ASSEMBLIES FOR |
| | INSULATED AND NON-INSULATED DECKS, AS WELL AS, |
| | DIFFERENT FASTENING OPTIONS AND DESIGN PRESSURES. |
| | THEREFORE, THE ASSEMBLY, FASTENING OPTION AND DESIGN |
| | PRESSURE ARE REQUIRED TO BE SPECIFIED. THIS CAN BE |
| | ACCOMPLISHED BY CIRCLING THE APPROPRIATE ITEMS ON THE |
| | NOA. ALSO NOTE THAT RAS 117 CALCULATIONS MAY BE |
| | REQUIRED FOR PERIMETER AND CORNER AREAS, ROOF ZONES 2 |
| | AND 3 RESPECTIVELY. SEE LIMITATION NUMBER 7 OF THE |
| | NOA. |
| | |
| | 11) THE PRODUCT INFORMATION ON C1 HAS BEEN REVISED AND |
| | UPDATED. PLEASE REMOVE IT OR CORRECT IT. |
| | |
| | 12)PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SUBMIT 2 COPIES OF THE |
| | PRODUCT APPROVALS. THE FLORIDA COVERSHEET AND NOA OR |
| | OTHER EVALUATION IS REQUIRED. PRODUCT APPROVALS ARE |
| | REQUIRED FOR EXTERIOR DOORS AND WINDOWS, ROOF |
| | COVERINGS, STORM PANELS, TRUSS HANGERS, CONNECTORS AND |
| | STRAPS AND OTHER PRODUCTS LISTED BY RULE 9B-72. |
| | |
| | 13)WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 14)IF THE GLAZED OPENINGS ARE NOT IMPACT RESISTANT |
| | SUBMIT PRODUCT APPROVALS, KEY PLANS AND INSTALLATION |
| | SCHEDULES ( INCLUDE FASTENER TYPES, SPACING ,ETC.) FOR |
| | THE STORM PANELS. |
| | |
| | 15)TWO SETS OF SIGNED AND SEALED PLANS, PRODUCT |
| | APPROVALS, ENERGY FORMS, ETC. OR REQUIRED. |
| | |
| | 16) THE INFORMATION SUBMITTED FOR THE WINDOWS IS NOT |
| | ACCEPTABLE. IT IS INCOMPLETE AND HAS BEEN REVISED. |
| | |
| | 17) PLEASE RESUBMIT THE PLAN SHEETS WITH THE COUNTY |
| | IMPACT FEE STAMPS OR HAVE THE NEW REVISED SHEETS |
| | STAMPED FOR IMPACT FEES. |
| | |
| | 18) ONE SET OF THE OLD PLANS CAN BE RESUBMITTED FOR |
| | REFERENCE PURPOSES. |
| | |