| Date |
Text |
| 2007-04-12 15:11:16 | BUILDING PLAN REVIEW |
| | PERMIT: 06090011 |
| | ADD: 444 W RAILROAD AVE |
| | CONT: PBM DEVELOPMENT |
| | TEL: (561) 7151800 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RD REVIEW |
| | ACTION: DENIED |
| | |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) PLEASE PROVIDE A CURRENT NOC. FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| | THE COURT. |
| | NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3)SHOP DRAWINGS SUBMITTED BY STEADFAST BRIDGES ARE |
| | SEALED COPIES OF SIGNATURE NOT ORIGINAL SIGNATURES. |
| | PLANS, SPECIFICATIONS, REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | 4) PLEASE SEE THE CALCULATIONS SUBMITTED FROM ROBERT G. |
| | GRAHAMIII PAGE 39 BASIC LOAD CASES # 8 LL-PEDESTRIAN |
| | THE DISTRIBUTED LOAD INDICATES 22. TABLE 1607.1 # 39 |
| | WALKWAYS AND ELEVATED PLATFORMS INDICATES A MINIMUM |
| | LIVE LOAD OF 60PSF NOT 22. |
| | PLEASE CLARIFY. THE OTHER QUESTION ABOUT LIVE LOADS |
| | SHEET SHOP DRAWING SHEET# 1 IS THE STATEMENT LIGHT |
| | VEHICLE MAXIMUM LOAD 4 TONS IS THIS TO BE CONSIDERED A |
| | POINT LOADING? |
| | |
| | 5) SHOP DRAWINGS (STEADFAST BRIDGES & ROOFING REPORT) |
| | SHALL HAVE BEEN REVIEWED BY THE DESIGNER OF RECORD AND |
| | THEIR SHOP DRAWING STAMP AFFIXED WITH APPROVAL OR WITH |
| | COMMENTS PRIOR TO SUBMITTAL TO THE CITY. |
| | WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL.(ROOFING REPORT). |
| | |
| | 6)SHEET S0.1 PEDESTRIAN BRIDGE HEADING, STILL |
| | INDICATES DESIGNED UNDER THE 2001 FBC AND ASCE 7-98, |
| | PLEASE CORRECT. |
| | |
| | 7) CALCULATION BOOKLET COVER SHEET ALSO HAS A RAISED |
| | SEALCOPIED SIGNATURE : |
| | PLANS, SPECIFICATIONS, REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND |
| | BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |