| 2007-01-09 11:22:34 | DENIED 2ND TIME |
| | REFERENCE: FBC-2001 PLUMBING |
| | |
| | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING |
| | PLAN REVIEW ON THE RESUBMITTED SHEET P2 SANITARY RISER |
| | DIAGRAM TO MEET CODE COMPLIANCE: |
| | |
| | 1.SHEET P2 FIRST FLOOR UNIT #1: A} VENT REQUIRED FOR |
| | DOUBLE BOWL SINK W/DISHWASHER PER FBC-2001 PLUMBING, |
| | SEC. 901.2.1 B} PLEASE INDICATE DOUBLE BOWL SINK |
| | W/DISHWASHER AND ADD DRAIN FOR DISHWASHER PER FBC-2001 |
| | SEC. 409.3.1. |
| | |
| | 2.SHEET P2 FIRST FLOOR UNIT #2: A} VENT REQUIRED FOR |
| | DOUBLE BOWL SINK W/DISHWASHER PER FBC-2001 PLUMBING, |
| | SEC. 901.2.1. B} PLEASE INDICATE DOUBLE BOWL SINK |
| | W/DISHWASHER AND ADD DRAIN FOR DISHWASHER PER FBC-2001 |
| | PLUMBING SEC. 409.3.1. |
| | |
| | 3. SHEET P2 SECOND FLOOR UNIT #3: A} VENT REQUIRED FOR |
| | BATHROOM GROUP PER FBC-2001 PLUMBING SEC. 909.1. B} |
| | PLEASE INDICATE DOUBLE BOWL SINK W/ DISHWASHER AND ADD |
| | DRAIN FOR DISHWASHER PER FBC-2001 PLUMBING SEC. |
| | 409.3.1. |
| | |
| | 4. SHEET P2 GARAGE WASHING MACHINE: A} PLEASE INDICATE |
| | STANDPIPE FOR WASHING MACHINE DRAIN PER FBC-2001 |
| | PLUMBING, SEC. 802.4. B} PLEASE INDICATE CLEANOUT FOR |
| | WASHING MACHINE AT FOUR FEET ABOVE FINNISH FLOOR (4' |
| | A.F.F.) PER FBC-2001 PLUMBING SEC. 708.10. |
| | |
| | **********IMPORTANT INFORMATION |
| | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. NOTE: ONLY ONE CORRECTED DRAWING |
| | IN RED INK FOR REFERENCE FOR |
| | RESUBMITTAL. |
| | |
| | END OF COMMENTS: |
| | |