Plan Review Notes
Plan Review Notes For Permit 06082188
Permit Number 06082188
Review Stop B
Sequence Number 2
Notes
Date Text
2007-02-26 09:45:43****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004
 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
  
 1.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025 FOR MORE
 INFORMATION.
  
 2.-4.)ADDRESSED.
  
 5.)SEPARATE PERMIT REQUIRED FOR THE
 DUMPSTER ENCLOSURE.PLEASE COMPLETE A
 PERMIT APPLICATION; SEPARATE PLANS ARE
 NOT REQUIRED.
  
 6-10.)ADDRESSED.
  
 11.)SEE FBC313, FBC406.1.FROM PREVIOUS LIST,
 PENETRATIONS TO BE IN COMPLIANCE WITH FBC M712
 (M1-01-101).THE EXHAUST FAN LOUVER IS NOT IN
 COMPLIANCE.HOWEVER, AFTER FIRTHER DISCUSSION WITH
 HAROLD MOSER, CHIEF MECHANICAL INSPECTOR, THE EXHAUSE
 SHOULD DISCHARGE TO THE OUTSIDE, FBC MECHANICAL 501.2.
  
  
 1 HOUR OCCUPANCY VERTICAL SEPARATION IS SHOWN BETWEEN
 THE GARAGE AND BUSINESS AREA; PLEASE SHOW HORIZONTAL
 SEPARATION BETWEEN THE FIRST AND SECOND FLOOR, EITHER
 TESTED ASSEMBLY OR CALCULATED FIRE RESISTANCE.
  
 12-16.)ADDRESSED.
  
 17.)SECTION 2-A6-00-101, THE STAIR
 RAIL IS TO EITHER BE ROUNDED OR RETURN
 TO THE FLOOR, WALL, OR POST.A STRAIGHT
 EXTENSION IS SHOWN.
  
 SECOND REVIEW; THE STAIR RAILING DETAIL ISN'T CLEAR.
 HANDRAIL AND GUARDRAIL ARE REQUIRED FBC1012.1,
 FBC1009.11.ONLY ONE RAIL IS SHOWN.IT APPEARS THAT
 THE RAILING EXTENSION IS NOT ROUNDED, SEE FBC11 FIGURE
 19.
  
 18.)SECTION 2-A6-00-101, THE AREA
 UNDER THE STAIR LACKS THE HEADROOM
 REQUIRED BY FBC11-4.4.2, BARRIER
 REQUIRED.
  
 19.-22.)ADDRESSED.
  
 23.)STRUCTURALS STATE THAT MRH IS
 24FT.NOTE THAT THE STAIR ROOF IS AT APPROXIMATELY
 37FT.DESIGN PRESSURES
 APPEAR COMPLIANT AS THE HIGHER SECTION
 IS A PITCHED ROOF, BUT PLEASE ADDRESS ON
 THE PLAN.
  
 THE RESPONSE LETTER STATES THAT THERE IS A
 CLARIFICATION LETTER IN THE PACKAGE.PER DISCUSSION
 WITH THE ENGINEER, THE LETTER WILL BE PROVIDED TO
 PREVENT FIELD ISSUES (INSPECTIONS).
  
 24.)ON THE YHS 50 STOREFRONT PRODUCT
 APPROVAL, INDICATE WHICH PRODUCT YOU ARE
 USING AS NOT ALL MEET WORST CASE FOR
 WIND LOADS.
  
 THE YHS 50 STOREFRONT PRODUCT APPROVALS WERE NOT
 RESUBMITTED.ANY PRODUCT APPROVALS NOT REVIEWED PRIOR
 TO PERMIT ISSUANCE WILL REQUIRE SEPARATE PERMITS.
  
 25-26.)ADDRESSED.
  
 27.)ANY PRODUCT APPROVALS REQUIRED BY
 FAC9B72 AND NOT SUBMITTED PRIOR TO
 PERMIT ISSUANCE WILL REQUIRE SEPARATE
 PERMITS; FOR INSTANCE, THE FLAT DECK
 ROOF AND THE EXTERIOR METAL DOORS.FOR
 THE FLAT DECK, INDICATE WHICH APPROVED
 ASSEMBLY YOU WILL BE USING.
  
 28.)ADDRESSED.
  
 NEW COMMENTS:
  
 29.)SEE ELECTRIC COMMENTS REGARDING THE ENERGY CALCS.
 ALSO PLEASE CLARIFY CONFLICT BETWEEN THE SQUARE FOOT
 AREA ON THE PLAN AND THE ENERGY CALC SQUARE FOOT AREA.
  