| 2007-02-26 09:45:43 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC RFLORIDA BUILDING CODE 2004 |
| | RESIDENTIAL |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | |
| | 1.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE STAMPED |
| | AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION.233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2.-4.)ADDRESSED. |
| | |
| | 5.)SEPARATE PERMIT REQUIRED FOR THE |
| | DUMPSTER ENCLOSURE.PLEASE COMPLETE A |
| | PERMIT APPLICATION; SEPARATE PLANS ARE |
| | NOT REQUIRED. |
| | |
| | 6-10.)ADDRESSED. |
| | |
| | 11.)SEE FBC313, FBC406.1.FROM PREVIOUS LIST, |
| | PENETRATIONS TO BE IN COMPLIANCE WITH FBC M712 |
| | (M1-01-101).THE EXHAUST FAN LOUVER IS NOT IN |
| | COMPLIANCE.HOWEVER, AFTER FIRTHER DISCUSSION WITH |
| | HAROLD MOSER, CHIEF MECHANICAL INSPECTOR, THE EXHAUSE |
| | SHOULD DISCHARGE TO THE OUTSIDE, FBC MECHANICAL 501.2. |
| | |
| | |
| | 1 HOUR OCCUPANCY VERTICAL SEPARATION IS SHOWN BETWEEN |
| | THE GARAGE AND BUSINESS AREA; PLEASE SHOW HORIZONTAL |
| | SEPARATION BETWEEN THE FIRST AND SECOND FLOOR, EITHER |
| | TESTED ASSEMBLY OR CALCULATED FIRE RESISTANCE. |
| | |
| | 12-16.)ADDRESSED. |
| | |
| | 17.)SECTION 2-A6-00-101, THE STAIR |
| | RAIL IS TO EITHER BE ROUNDED OR RETURN |
| | TO THE FLOOR, WALL, OR POST.A STRAIGHT |
| | EXTENSION IS SHOWN. |
| | |
| | SECOND REVIEW; THE STAIR RAILING DETAIL ISN'T CLEAR. |
| | HANDRAIL AND GUARDRAIL ARE REQUIRED FBC1012.1, |
| | FBC1009.11.ONLY ONE RAIL IS SHOWN.IT APPEARS THAT |
| | THE RAILING EXTENSION IS NOT ROUNDED, SEE FBC11 FIGURE |
| | 19. |
| | |
| | 18.)SECTION 2-A6-00-101, THE AREA |
| | UNDER THE STAIR LACKS THE HEADROOM |
| | REQUIRED BY FBC11-4.4.2, BARRIER |
| | REQUIRED. |
| | |
| | 19.-22.)ADDRESSED. |
| | |
| | 23.)STRUCTURALS STATE THAT MRH IS |
| | 24FT.NOTE THAT THE STAIR ROOF IS AT APPROXIMATELY |
| | 37FT.DESIGN PRESSURES |
| | APPEAR COMPLIANT AS THE HIGHER SECTION |
| | IS A PITCHED ROOF, BUT PLEASE ADDRESS ON |
| | THE PLAN. |
| | |
| | THE RESPONSE LETTER STATES THAT THERE IS A |
| | CLARIFICATION LETTER IN THE PACKAGE.PER DISCUSSION |
| | WITH THE ENGINEER, THE LETTER WILL BE PROVIDED TO |
| | PREVENT FIELD ISSUES (INSPECTIONS). |
| | |
| | 24.)ON THE YHS 50 STOREFRONT PRODUCT |
| | APPROVAL, INDICATE WHICH PRODUCT YOU ARE |
| | USING AS NOT ALL MEET WORST CASE FOR |
| | WIND LOADS. |
| | |
| | THE YHS 50 STOREFRONT PRODUCT APPROVALS WERE NOT |
| | RESUBMITTED.ANY PRODUCT APPROVALS NOT REVIEWED PRIOR |
| | TO PERMIT ISSUANCE WILL REQUIRE SEPARATE PERMITS. |
| | |
| | 25-26.)ADDRESSED. |
| | |
| | 27.)ANY PRODUCT APPROVALS REQUIRED BY |
| | FAC9B72 AND NOT SUBMITTED PRIOR TO |
| | PERMIT ISSUANCE WILL REQUIRE SEPARATE |
| | PERMITS; FOR INSTANCE, THE FLAT DECK |
| | ROOF AND THE EXTERIOR METAL DOORS.FOR |
| | THE FLAT DECK, INDICATE WHICH APPROVED |
| | ASSEMBLY YOU WILL BE USING. |
| | |
| | 28.)ADDRESSED. |
| | |
| | NEW COMMENTS: |
| | |
| | 29.)SEE ELECTRIC COMMENTS REGARDING THE ENERGY CALCS. |
| | ALSO PLEASE CLARIFY CONFLICT BETWEEN THE SQUARE FOOT |
| | AREA ON THE PLAN AND THE ENERGY CALC SQUARE FOOT AREA. |
| | |