Plan Review Notes
Plan Review Notes For Permit 06082126
Permit Number 06082126
Review Stop B
Sequence Number 1
Notes
Date Text
2006-09-14 00:00:00 
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1) ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
 NOTE: THE GENEREAL NOTES REFER TO THE
 2001 FBC.
  
 2) R4101.6.1 CONFORMANCE STANDARD.
 DESIGN , CONSTRUCTION AND WORKMANSHIP
 SHALL BE IN CONFORMITY WITH THE
 REQUIREMENTS OF ANSI/NSPI 3; ANSI/NSPI
 4; ANSI/NSPI 5; AND ANSI/NSPI 6.
 ALSO SEE SEC.424 FBC. AND CH.41 RBC.
  
 3) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  
  
  
  