Plan Review Notes
Plan Review Notes For Permit 06082089
Permit Number 06082089
Review Stop B
Sequence Number 3
Notes
Date Text
2007-04-02 16:10:10****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA
  
 1.)THE PLANTATION SHUTTER DOORS AT THE PRIVATE DINING
 AREA DO NOT COMPLY WITH FBC11-4.13,FBC1008.1.2.
  
 2.)A4.2, RAMP HANDRAIL IS TO COMPLY WITH
 FBC11-4.8.5(2).H6 SHOWS 1'1" EXTENSION AT THE TOP.
  
 3.)SEE C6-A4.2, FBC11-4.8.5(6).COMPLIANCE IS NOT
 CLEAR; PROVIDE A DETAIL.ALSO SEE FBC11 FIGURE 17.
  
 4.)POS, A1.1, PROVIDE A DETAIL.SEE FBC11-7.2.
  
 5.)N/A (REMOVED)
  
 6.)FBC11-4.8.4(2), SHOW THE DIMENSION OF THE LANDING
 AT THE TOP OF THE RAMP.
  
 7.)A1.1, C7-A3.1, THESE DINING AREAS ON THE RAISED
 PLATFORM ARE NOT ACCESSIBLE, FBC11-5.1,
 FBC11-4.1.2(2).
  
 8.)WHAT IS AT COLUMN LINE BETWEEN B-8, B8.1?THIS
 APPEARS TO BE A RAMP WITH NONCOMPLIANT RAILINGS.SEE
 FBC11-4.1.2(2).PROVIDE DETAILS FOR THE RAMP,
 HANDRAILS.
  
 9.)A5.1, SHOW MANEUVERING CLEARANCE FOR THE DOOR AT
 THE KITCHEN.AS THE DOORS ARE NOT LABELED, AND THERE
 AREN'T ANY CROSS COLUMN LINES IN THIS AREA, IT IS
 DIFFICULT TO DESCRIBE WHICH DOOR THIS CORRECTION
 APPLIES TO SO TO AVOID CONFUSION PLEASE SHOW FOR ALL.
 NOTE THAT A1.1 SHOWS THIS AREA AS CLEAR, A5.1 SHOWS
 THIS AREA OBSTRUCTED WITH SQUARES.WHAT IS THIS?
  
 10.)SEE FBC11-4.32, AND FBC11-5.1-11-5.3, FBC11
 FIGURE 46.SHOW COMPLIANCE ON THE PLAN; NO
 ACCESSIBLITITY DETAILS, PATH, ETC. WERE PROVIDED.