| 2006-08-18 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL AS REQUIRED BY DCA RULE 9B-72 | | | FOR FLAT ROOF SYSTEM TO BE INSTALLED. | | | SEE ATTACHED COPY OF CITY POLICY FOR | | | RE-ROOFING PERMITS AND PROVIDE ALL THE | | | INFORMATION REQUESTED. | | | | | | 2- FLAT ROOFS ASSEMBLIES TYPICALLY | | | REQUIRE NAIL ENHANCING AT PERIMETER AND | | | CORNER AREAS. READ PRODUCT APPROVAL | | | GENERAL LIMITATIONS. IF GENERAL | | | LIMITATION #7 REQUIRES RAS 117 | | | CALCULATIONS TO BE PREPARED BY ANY OF | | | THE PROFESIONALS LISTED IN SUCH | | | LIMITATION, THEN PROVIDE SUCH | | | CALCULATIONS WITH ORIGINAL SEAL AND | | | SIGNATURE. IF RAS 117 CALCULATIONS ARE | | | NOT REQUIRED TO BE DONE BYREGISTERED | | | PROFESSIONALS, THEN PROVIDE SUCH | | | CALCULATIONS OR USE PALM BEACH COUNTY | | | PRESCRIPTIVE METHOD. | | | NOTE: GENERAL LIMITATION #9 DOESN'T | | | ALLOW NAIL ENHANCING, THEREFORE, SYSTEM | | | MAY NOT BE USED IN THIS AREA. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (5610805-6712 |
|