| Plan Review Notes For Permit 06080547 |
| Permit Number |
06080547 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-08-26 00:00:00 | | | | 1) SUBMIT DETAIL DRAWINGS SHOWING HOW | | | THE NEW WINDOWS WILL BE INSTALLED AT THE | | | SCREEN ENCLOSURRE. SHOW THE HEADDER | | | DETAIL AND OPENING DIMENTION OF EACH | | | WINDOW.THOSE WINDOWS WHICH ARE | | | NON-IMPACT REQUIRES HURRICANE | | | PROTECTION. PROVIDE A FLOOR LAYOUT OF | | | THE BUILDING SHOWING THE LOCATION OF | | | EACH WINDOW. | | | | | | 2) 2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 |
|