| 2006-09-19 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1- BRING PLANS TO PALM BEACH COUNTY TO |
| | VERIFY IF IMPACT FEES ARE DUE OR NOT. |
| | BRING BACK STAMPED PLANS AND COPY OF |
| | PAID RECEIPT. |
| | |
| | 2- PROVIDE COMPLETE STRUCTURAL DETAIL AT |
| | NEW CUT OUT OPENING FOR NEW DOOR AT |
| | KITCHEN AREA. SEC. 106.1.2 CITY |
| | AMENDMENTS TO FBC 2004. |
| | |
| | 3- PROVIDE TRUSS DRAWINGS FOR REVIEW |
| | PRIOR TO INSTALLATION AS REQUIRED BY |
| | SEC. R802.10.1 2004 RESIDENTIAL CODE. |
| | ***NOTE: ARCHITECT TO REVIEW AND APPROVE |
| | ALL TRUSS DRAWINGS PRIOR TO SUBMITTAL TO |
| | THIS OFFICE. |
| | |
| | 4- WALL SECTION: |
| | A) SHOW THE 6" MIN. CLEARANCE FROM |
| | GRADE AS REQUIRED BY SEC. R319.1(5) 2004 |
| | RESIDENTIAL CODE. |
| | B) SPECIFY WALL SHEATHING FASTENING. |
| | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 |
| | C) CLARIFY CONNECTOR PAHD22. SEE SIMPSON |
| | CATALOGUE FOR CORRECT SPECS. |
| | D) CLARIFY IF 4"X8" WOOD BEAM IS |
| | EXISTING OR NEW?. IF NEW, THEN PROVIDE |
| | STRUCTURAL CONNECTORS AT THE ENDS. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | E) TRUSS CONNECTOR SIZE TO MATCH TRUSS |
| | ANCHOR SCHEDULE. REVISE AS REQUIRED. |
| | F) SPECIFY CONNECTION OF 2"X4" STUDS TO |
| | BOTTOM OF EXISTING 4"X10" WOOD BEAM. |
| | SEC. 106.1.2 CITY AMENDMENTS TO FBC. |
| | |
| | 5- TRUSS ANCHOR SCHEDULE: SEE CURRENT |
| | SIMPSON CATALOGUE FOR CORRECT SIZE, |
| | NUMBER OF NAILS, UPLIFT AND LATERAL |
| | LOADS AND REVISE SCHEDULE AS REQ'D. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 6- PROVIDE ENERGY CALCULATIONS WITH |
| | COMPLETE INFORMATION ON TOP OF FORM. |
| | ALSO, OWNER/AGENT TO SIGN AND DATE FORM. |
| | |
| | 7- PROVIDE FLORIDA OR LOCAL PRODUCT |
| | APPROVAL AS REQUIRED BY DCA RULE 9B-72 |
| | FOR ALL SIMPSON STRUCTURAL CONNECTORS |
| | SPECIFIED ON PLANS AND DETAILS. |
| | |
| | 8- ARCHITECT TO REVIEW AND APPROVE IN |
| | WRITTING ALL PRODUCT APPROVALS AS REQ'D |
| | BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| | |
| | 9- ARCHITECT NEEDS TO PROVIDE IN THE |
| | TITLE BLOCK ALL THE MIN. INFORMATION |
| | REQUIRED BY FLORIDA ADMINISTRATIVE CODE |
| | SEC. 61G1-16.004. SEE ATTACHED COPY. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |