| 2006-09-14 00:00:00 | |
| | |
| | DENIED |
| | |
| | 1)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SETS OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561) 233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 2) THE STATE OF FLORIDA REQUIRES |
| | COLLECTION OF A RADON SURCHARGE ON ALL |
| | NEW CONSTRUCTION COMPUTED ON UNDER ROOF |
| | FLOOR SPACE PER 10D-91 FAC. THESE FEES |
| | WILL BE ADDED TO THE PERMIT APPLICATION |
| | FEES |
| | |
| | 3) THE CLAIMED VALUATION ON THE PERMIT |
| | APPLICATION IS LOW. FOR PERMITTING |
| | PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| | COST EXCLUDING LAND VALUE. OUR VALUATION |
| | REFERENCE IS ICC (BVD), MARSHALL-SWIFT |
| | AND MEANS COST ANALYSIS SERVICES PER |
| | 108.3 FBC* |
| | |
| | 4) INDEX SHEET REQUIES UPDATED |
| | INFORMATION ON THE FRONT AND SIDE |
| | SETBACKS THAT ARE PROVIDED |
| | |
| | 5) THE MIN SOIL BEARING CAPACITY THAT IS |
| | REQUIRED BY THE DESIGNER (2500 PSF) AND |
| | THE SOIL BEARING CAPACITY IN THE SOIL |
| | REPORT (2000) DO NOT MATCH |
| | |
| | 6) PLEASE SUBMIT 2 COPIES OF ALL |
| | CONSTRUTION DOCUMENTS THIS INCLUDES SOIL |
| | REPORTS, SURVEYS, ENERGY CALC'S, PRODUCT |
| | APPROVALS, ETC. |
| | |
| | 7) THE PERMIT APPLICATION SHALL INCLUDE |
| | TWO COPIES OF EACH PRODUCT APPROVAL THAT |
| | IS RELEVANT PER 9B-72. THESE SHOULD |
| | INCLUDE THE FLORIDA STATE APPROVAL COVER |
| | PAGES, AND THE PRODUCT NOA THAT LISTS |
| | THE SYSTEM COMPONENTS/ FASTENER LIST |
| | PAGES, THE PAGES WITH THE CHOSEN |
| | ASSEMBLY/ SYSTEM TO BE USED AND THE |
| | GENERAL LIMITATIONS PAGE. ALL CAN BE |
| | FOUND ON WWW.FLORIDABUILDING.ORG |
| | |
| | 8) THOSE PRODUCTS WHICH ARE REGULATED BY |
| | DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | 9) PRODUCT APPROVALS THAT WERE SUBMITTED |
| | SHALL BE SUBMITTED WITH THE STATE COVER |
| | SHEETS WHERE APPLICABLE |
| | |
| | 10) PRODUCT APPROVALS WERE SUBMITTED FOR |
| | HORIZONTAL SLIDING WINDOWS AND NONE ARE |
| | PRESNT ON THE DRAWINGS |
| | |
| | 11) THE FOLLOWING PRODUCT APPROVALS ARE |
| | MISSING FROM THE PACKAGE (SH WINDOWS, |
| | MULLIONS FOR WINDOWS THAT ARE JIONED |
| | TOGETHER, FRENCH DOORS,SLIDING GLASS |
| | DOORS,WOOD ANCHORS AND TIES |
| | |
| | 12) SUBMIT ENGINEERED TRUSS DRAWINGS |
| | THAT COMPLY WITH R802.10.1 FBC WITH |
| | PERMIT APPLICATION OR BEFORE |
| | INSTALLATION THAT HAVE BEEN REVIEWED AND |
| | APPROVED BY THE DESIGNER OF RECORD |
| | |
| | 13) PROVIDE AT MINIMUM 1 ACCESSIBLE |
| | BATHROOM PER R322.1.1 FBC |
| | |
| | 14) THE SH24 WINDOWS SPECIFIED ON THE |
| | DRAWINGS DO NOT MEET THE REQUIREMENTS |
| | FOR EMERGENCY EGRESS AS STIPULATED PER |
| | R310.1 - R310.1.4 FBC |
| | |
| | 15) PROVIDE ATTIC ACCESS ON DRAWINGS PER |
| | R807.1 |
| | |
| | 16) PROVIDE MIN ROOF SHEATHING |
| | ATTACHMENT PER TABLE 2304.9.1 FBC |
| | |
| | 17) PROVIDE BUCK ATTACHMENT DETAIL FOR |
| | 2X BUCKS AS MANY INSTALLATIONS USE 2X |
| | INSTEAD OF 1X, ALSO NOTE THAT BUCK FOR |
| | GARAGE DOOR AS PER NOA |
| | |
| | 18) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |