| Date |
Text |
| 2006-09-07 00:00:00 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. OWNER/BUILDER DISCLOSURE STATEMENT |
| | CHAPTER 489, PART 1, FLORIDA STATUTES, |
| | STATES IN PART, "THE BUILDING OR |
| | RESIDENCE MUST BE FOR YOUR OWN USE OR |
| | OCCUPANCE". THIS DOES NOT SEEM TO BE THE |
| | CASE. CONTRACTORS SHALL BE REQUIRED TO |
| | PULL PERMITS FOR THIS WORK. |
| | |
| | 2. SHT A-1 SECTION 11-4.17.3 EXCEPTION |
| | (1) THE STANDARD ACCESSIBLE RESTROOM |
| | STALL SHALL CONTAIN AN ACCESSIBLE |
| | LAVATORY WITHIN IT, THE SIZE OF SUCH |
| | LAVATORY TO BE NOT LESS THAN 19 INCHES |
| | WIDE BY 17 INCHES DEEP NOMINAL SIZE, AND |
| | WALL MOUNTED. THE LAVATORY SHALL BE |
| | MOUNTED SO AS NOT TO OVERLAP THE CLEAR |
| | FLOOR SPACE AREAS REQUIRED BY SECTION |
| | 11-4.17 (SEE FIGURE 11-30(A) AND |
| | 11-30)E) AND TO COMPLY WITH SECTION |
| | 11-4.19 OF THE CODE. SUCH LAVATORIES |
| | SHALL BE COUNTED AS PART OF THE REQUIRED |
| | FIXTURE COUNT FOR THE BUILDING. |
| | (2) THE ACCESSIBLE WATER CLOSET SHALL BE |
| | LOCATED IN THE CORNER, DIAGONAL TO THE |
| | DOOR. |
| | |
| | 3. SUBMIT A TOILET ROOM DETAIL SHOWING |
| | THE FOLLOWING: |
| | FOR W/C'S |
| | A. 11-4.16.2 CLEAR FLOOR SPACE |
| | B. 11-4.16.3 HEIGHT |
| | C. 11-4.16.4 GRAB BARS |
| | D. 11-4.16.5 FLUSH CONTROLS |
| | E. 11-4.16.6 DISPENSERS |
| | FOR LAV'S |
| | A. 11-4.19.2 HEIGHT & CLEARANCES |
| | B. 11-4.19.3 CLEAR FLOOR SPACE |
| | C. 11-4.19.4 EXPOSED PIPES & SURFACES |
| | D. 11-4.19.5 FAUCETS |
| | E. 11-4.19.7 MIRRORS |
| | FOR TOILET ROOM |
| | A. 11-4.22.3 AN UNOBSTRUCTED TURNING |
| | SPACE COMPLYING WITH SECTION 11-4.2.3 |
| | SHALL BE PROVIDED WITHIN AN ACCESSIBLE |
| | TOILET ROOM. - PROVIDE INFORMATION BOTH |
| | ON A FLOOR PLAN AND WALL ELEVATIONS. |
| | SECTION 106.1.1. |
| | |
| | 4. THERE ARE GUIDELINES FOR BUILDING |
| | ELEMENTS FOR CHILDREN, ADAAG AMENDMENTS |
| | THAT PROVIDE FOR FIXTURES THAT ARE |
| | ACCESSIBLE TO SMALLER CHILDERN OF |
| | DIFFERENT AGES. THESE ARE GUIDELINES, |
| | BUT IT IS SUGGESTED THAT STANDARD |
| | FIXTURES BE SUBSTITUDED FOR THESE. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| 2006-08-21 00:00:00 | PER KEN STEVENS ROUTEBACK TO INCOMMING |