Plan Review Notes
Plan Review Notes For Permit 06080143
Permit Number 06080143
Review Stop B
Sequence Number 1
Notes
Date Text
2006-08-31 00:00:00BUILDING PLAN REVIEW
 PERMIT:06080143
 ADD: 5405 N. HAVERHILL RD.
 CONT: G. W. PURUCKER HOMES INC.
 TEL: (561)775-1170
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601, AND LEVEL OF ALTERATION
 UNDER 2004 FL EXISTING BLDG
 CODE.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 3) ADDITIONAL INFORMATION REQUIRED,
 106.1.2*. PLANS INDICATE THERE IS A
 MEZZANINE LEVEL, PROVIDE WHAT WALLS ARE
 EXISTING AND WHAT WALLS ARE NEW FIRST
 FLOOR AND MEZZANINE LEVEL.
 BOTH THE FIRST FLOOR AND MEZZANINE
 LEVELS CAN NOT BE TOTALY ENCLOSED.
 MEZZANINES BY DEFINTION NEED TO
 COMMUNICATE WITH THE ROOM THAT IT IS
 LOCATED. EITHER THE FLOORS CAN NOT BE
 ENCLOSED ONLY ONE. 505.2. EVEN IF THE
 EXCEPTION# 1 OF 505.4 THE AMOUNT OF
 OPENNESS REQUIRED THE OCCUPANT LOAD FOR
 THE MEZZANINE WOULD BE OVER 10
 OCCUPANTS. THE CONFERENCE ROOM ALONE
 148SQ FT @ 15 SQ FT / PERSON ALONE WOULD
 BE AN OCCUPANT LOAD OF 10 PLUS THE
 REMAINDER OF THE FLOOR. IF EXCEPTION# 3
 IS TAKEN ONLY 10% OF THE MEZZANINE FLOOR
 AREA CAN BE ENCLOSED.
  
 4) THESE UNITS ARE CONDOMINIMUM
 REQUIRING A UNITY OF TITLE BETWEEN
 UNITS. THE PROPOSED BUILDING (UNIT)
 STRUCTURE TRANSGRESSES LEGAL BOUNDARY
 LINES BETWEEN THE LOTS WHICH COMBINE TO
 FORM 'THE SITE'.A 'UNITY OF TITLE'
 SHALL BE RECORDED AT THE COUNTY
 COURTHOUSE. SUBMIT A COPY OF THE
 RECORDED 'UNITY OF OF TITLE' DOCUMENT SO
 THAT FBC TABLE 600 BOUNDARY LINE
 REQUIREMENTS MAY BE DEEMED NOT
 APPLICABLE.
  
 5) DUTY TO PROVIDE VERTICAL
 ACCESSIBILITY:11-4.1.6(1)(F)
 NOTHING IN THIS SECTION SHALL BE
 CONSTRUED TO RELIEVE THE OWNER OF ANY
 BUILDING, STRUCTURE OR FACILITY FROM THE
 DUTY TO PROVIDE VERTICAL ACCESSIBILITY
 TO ALL LEVELS ABOVE AND BELOW OCCUPIABLE
 GRADE LEVEL, REGARDLESS OF WHETHER THE
 CODE REQUIRES AN ELEVATOR TO BE
 INSTALLED IN SUCH BUILDING, STRUCTURE,
 OR FACILITY, EXCEPT FOR: (1) ELEVATOR
 PITS, ELEVATOR PENTHOUSES, MECHANICAL
 ROOMS, PIPING OR EQUIPMENT CATWALKS, AND AUTOMOBILE
 LUBRICATION AND MAINTENANCE
 PITS AND PLATFORMS; (2) UNOCCUPIABLE
 SPACES, SUCH AS ROOMS, ENCLOSED SPACES,
 AND STORAGE SPACES THAT ARE NOT DESIGNED
 FOR HUMAN OCCUPANCY, FOR PUBLIC
 ACCOMMODATIONS, OR FOR WORK AREAS; AND
 (3) OCCUPIABLE SPACES AND ROOMS THAT ARE
 NOT OPEN TO THE PUBLIC AND THAT HOUSE NO
 MORE THAN FIVE PERSONS INCLUDING, BUT
 NOT LIMITED TO, EQUIPMENT CONTROL ROOMS
 AND PROJECTION BOOTHS. HOWEVER, AS
 PROVIDED IN SECTION 553.509, FLORIDA
 STATUTES , BUILDINGS, STRUCTURES, AND
 FACILITIES MUST, AT A MINIMUM, COMPLY
 WITH THE REQUIREMENTS OF THE ADAAG.
 THEREFORE, FACILITIES SUBJECT TO THE
 ADAAG MAY BE REQUIRED TO PROVIDE
 VERTICAL ACCESS TO AREAS OTHERWISE
 EXEMPT UNDER SECTION 11-4.1.3 (5) OF
 THIS CODE.
  
 6)TO CLASSIFY THIS SPACE AS A TWO
 STORY
 UNIT, A EXIT TO THE EXTERIOR WILL BE
 REQUIRED. 1017.2.2 ARRANGEMENT.
 EXTERIOR EXIT DOORS SHALL LEAD DIRECTLY
 TO THE EXIT DISCHARGE OR THE PUBLIC
 WAY.1017.1 GENERAL.
  
 EXITS SHALL COMPLY WITH SECTIONS 1017
 THROUGH 1022 AND THE APPLICABLE
 REQUIREMENTS OF SECTIONS 1003 THROUGH
 1012 . AN EXIT SHALL NOT BE USED FOR ANY
 PURPOSE THAT INTERFERES WITH ITS
 FUNCTION AS A MEANS OF EGRESS. ONCE A
 GIVEN LEVEL OF EXIT PROTECTION IS
 ACHIEVED, SUCH LEVEL OF PROTECTION SHALL
 NOT BE REDUCED UNTIL ARRIVAL AT THE EXIT DISCHARGE.
 EXIT
 1017.2 EXTERIOR EXIT DOORS.
 BUILDINGS OR STRUCTURES USED FOR HUMAN
 OCCUPANCY SHALL HAVE AT LEAST ONE
 EXTERIOR DOOR THAT MEETS THE
 REQUIREMENTS OF SECTION 1008.1.1 .
  
 MORE COMMENTS MAY APPEAR AS A RESULT OF
 THE RESPONCE COMMENTS.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  