| Date |
Text |
| 2007-02-01 11:35:51 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | |
| | ****3RD REVIEW - FROM PREVIOUS REVIEWS: |
| | |
| | 1. SHT D-1 IN THE INSTALLATION OR |
| | REMOVAL OF ANY PART OF A DRAINAGE |
| | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. |
| | SECTION 704.5. INDICATE WHERE THE |
| | SANITARY PIPING WILL BE ABANDONED. POINT |
| | OF ABANDONMENT SHALL NOT BE COVERED |
| | PRIOR TO INSPECTIONS. |
| | ****RESPONSE NOTED.DETAIL 5 DOES NOT INDICATE WHERE |
| | THE FLOOR DRAINS HAVE BEEN DISCONNECTED FROM THE |
| | BUILDING DRAIN. PLEASE INDICATE WHERE THE FLOOR DRAINS |
| | WILL BE DISCONNECTED.DEMO INSPECTION WILL BE |
| | REQUIRED. |
| | ******RESPONSE NOTED, BUT THE NOTE INDICATING THAT THE |
| | FLOOR DRAINS WERE NOT CONNECTED TO THE SANITARY IS OF |
| | SOME CONCERN. IN A GARAGE AREA, THERE WOULD BE A |
| | REQUIREMENT FOR A SAND/OIL INTERCEPTOR, AND THERE IS |
| | ALSO A SECTION IN THE MUNICIPAL CODE THAT PROHIBITS |
| | CONNECTING FLOOR DRAINS IN A GARAGE TO THE STORM |
| | SYSTEM. VERIFICATION OF WHERE THE EXISTING FLOOR DRAINS |
| | ARE CONNECTED WILL BE REQUIRED. IF THE DRAINS ARE TO BE |
| | FILLED WITH CONCRETE, THE DRAIN PIPE SHALL BE |
| | DISCONNECTED AS THE DRAIN EXITS THE BUILDING, EITHER |
| | INSIDE OR OUTSIDE THE BUILDING. MR. RODNEY COMPO, |
| | ENVIRONMENTAL COMPLIANCE WILL BE CONTACTING THE |
| | CONTRACTOR AND OR OWNER TO VERIFY WHERE THE FLOOR |
| | DRAINS CONNECT. IF THERE IS AN OIL/SAND INTERCEPTOR, IT |
| | WILL BE ABANDONED PER CITY WEST PALM BEACH |
| | REQUIREMENTS. |
| | |
| | 2. OK |
| | |
| | 3. SHT A-5 WATER RISER DIAGRAM. THE |
| | WATER HAMMER ARRESTORS PROVIDED SHALL BE |
| | LOCATED NEAR THE FIXTURES IN AN |
| | "EFFECTIVE RANGE", NOT IN THE CEILING AS |
| | SHOWN. PDI-WH 201 AND MANUF. |
| | INSTALLATION INSTRUCTIONS. |
| | ****RESPONSE NOTED, BUT THE WATER HAMMER ARRESTORS ARE |
| | STILL SHOWN IN THE CEILING, NOT NEAR THE FIXTURE AS |
| | REQUIRED. |
| | ******RESPONSE NOTED, BUT THE WATER HAMMER ARRESTOR AT |
| | THE DRINKING FOUNTAIN IS STILL LOCATED IN THE CEILING. |
| | |
| | 4. OK |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6713 |