Plan Review Notes
Plan Review Notes For Permit 06080053
Permit Number 06080053
Review Stop B
Sequence Number 1
Notes
Date Text
2006-08-23 00:00:00DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE EXISTING BUILDING LEVEL OF
 ALTERATION IS LEVEL 2 NOT LEVEL 3. LEVEL
 3 ALTERATIONS APPLY WHERE THE WORK AREA
 EXCEEDS 50 PERCENT OF THE AGGREGATE AREA
 OF THE BUILDING AND MADE WITHIN ANY
 12-MONTH PERIOD.
  
 4) CLARIFY THAT A DOORWAY IS BEING
 CREATED BETWEEN THE EXISTING BEDROOM AND
  
 ENCLOSED CARPORT WHERE WINDOW IS BEING
 REMOVED.
  
 5) THE EMERGENCY EGRESS REQUIREMENT OF
 R310 MUST BE MAINTAINED IN THE EXISTING
 BEDROOM ADJACENT TO THE ENCLOSED GARAGE.
  
 6) GENERAL NOTE 3 ON SHEET 2 CALLS FOR
 8" MASONRY WALLS AND THE FLOOR PLAN
 SPECIFIES 2X4 FRAME WALLS 24" OC AND THE
 FOUNDATION PLAN ON SHEET 3 HAS FRAMING
 16"OC. PLEASE CORRECT.
  
 7) SPECIFY THE CONNECTORS THAT WILL BE
 USED TO ANCHOR THE NEW WALL TO TRUSSES
 AND NEW WALL TO EXISTING BEAM. 1/4" X 6"
 WOOD SCREWS DO NOT APPEAR TO BE ADEQUATE
 FOR UPLIFT.
  
 8) SPECIFY THE WASHER FOR THE ANCHOR
 BOLT AT THE BOTTOM PLATE. SEE R403.1.6.
  
 9) ANCHOR BOLTS ARE REQUIRED TO EXTEND A
 MINIMUM OF 7 INCHES INTO CONCRETE. SEE
 R403.1.6.
  
 10) R319.1 LOCATION REQUIRED.
 IN AREAS SUBJECT TO DECAY DAMAGE AS
 ESTABLISHED BY TABLE R301.2(1) , THE
 FOLLOWING LOCATIONS SHALL REQUIRE THE
 USE OF AN APPROVED SPECIES AND GRADE OF
 LUMBER, PRESSURE TREATED IN ACCORDANCE
 WITH AWPA C1, C2, C3, C4, C9, C15, C18,
 C22, C23, C24, C28, C31, C33, P1, P2 AND
 P3, OR DECAY-RESISTANT HEARTWOOD OF
 REDWOOD, BLACK LOCUST, OR CEDARS.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING
 HAVING A CLEARANCE OF LESS THAN 6 INCHES
 (152 MM) FROM THE GROUND.
 SPECIFY THE CLEARANCE FROM FINISH GRADE
 TO WALL SHEATHING AND FRAMING.
  
 11) SUBMIT ENERGY CALCULATION FORMS AS
 REQUIRED BY FBC 13-101.2.
  
 12) SPECIFY THE CEILING/ATTIC INSULATION
 ON THE PLANS.
  
 13) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SUBMIT
 PRODUCT APPROVALS FOR THE EXTERIOR
 WINDOW, DOOR AND STRUCTURAL CONNECTORS.
  
 14) W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 15) THE VALUE OF THE CONSTRUCTION HAS
 BEEN INCREASED TO $9343.OO BASED ON ICC
 CONSTRUCTION COST TABLE. INCLUDES LABOR
 AND MATERIAL COSTS CHARGED BY BUILDING
 CONTRACTORS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  