| Date |
Text |
| 2007-02-13 09:03:01 | REVISION DENIED |
| | REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY |
| | OF WEST PALM BEACH AMENDMENTS; FLORIDA ADMINISTRATIVE |
| | CODE; |
| | |
| | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING |
| | PLAN REVIEW ON THE REVISION TO MEET CODE COMPLIANCE: |
| | |
| | 1]FAC-61G1-16.004 TITLE BLOCK: |
| | A TITLE BLOCK MUST APPEAR ON ALL |
| | ARCHITECTURAL OR INTERIOR DESIGN |
| | DRAWINGS AND SPECIFICATION |
| | IDENTIFICATION SHEETS. THE TITLE BLOCK |
| | MUST, AT A MINIMUM, CONTAIN THE |
| | FOLLOWING INFORMATION: |
| | (1) FIRM NAME, ADDRESS, AND TELEPHONE |
| | NUMBER. |
| | (2) FIRM LICENSE NUMBER. |
| | (3) NAME OR IDENTIFICATION OF PROJECT. |
| | (4) DATE PREPARED. |
| | (5) A SPACE FOR THE SIGNATURE AND DATED |
| | SEAL. |
| | (6) A SPACE FOR THE PRINTED NAME OF THE |
| | PERSON SEALING THE DOCUMENT. |
| | NOTE: ON THE SUBMITTED REVISION THE FIRM LICENSE NUMBER |
| | IS MISSING, PLEASE CORRECT AND RESUBMIT. |
| | |
| | 2]PER FBC-2004 CHAPTER 1 SECTION 106.1.1 INFORMATION |
| | ON CONSTRUCTION |
| | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL |
| | BE OF SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE |
| | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, |
| | AS DETERMINED BY THE |
| | BUILDING OFFICIAL. |
| | NOTE: THE FOLLOWING INFORMATION NEEDS TO BE ON THE |
| | RESUBMITTED REVISION: |
| | A} PLEASE IDENTIFY ALL FIXTURES, LAUNDRY TRAY IS NOT |
| | IDENTIFIED, PLEASE CORRECT AND RESUBMIT. |
| | B} DISHWASHER IS MISSING FROM THE KITCHEN SINK, PLEASE |
| | CORRECT AND RESUBMIT. |
| | |
| | 3] PERFBC-2004 CHAPTER 1, SECTION 106.3.5.4 |
| | RESIDENTIAL (ONE AND TWO |
| | FAMILY) SUBMIT A PLUMBING SANITARY |
| | ISOMETRIC RISER DIAGRAM INDICATING ALL |
| | WASTE, VENTS, TRAPS WITH SIZES, AND |
| | CLEANOUT LOCATIONS. |
| | NOTE: THE FOLLOWING INFORMATION NEEDS TO BE INDICATED |
| | ON THE RESUBMITTED REVISION: |
| | A} NOT ALL PIPES OR TRAPS ARE SIZED, PLEASE CORRECT |
| | AND RESUBMIT. |
| | |
| | 4] PER FBC-2004 PLUMBING, SECTION 708 THE FOLLOWING |
| | NEEDS TO BE INDICATED ON THE RESUBMITTED REVISION. |
| | (A) 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| | BE THE SAME NOMINAL SIZE AS THE PIPE |
| | THEY SERVE UP TO 4 INCHES (102MM) |
| | CLEANOUT FOR WASHING MACHINE SHALL BE THREE INCH (3"), |
| | PLEASE INDICATE THIS ON THE RESUBMITTED REVISION. |
| | (B) 708.9 ACCESS. ACCESS SHALL BE |
| | PROVIDED TO ALL CLEANOUTS. |
| | CLEANOUT FOR THE WASHING MACHINE SHALL BE FOUR FEET |
| | ABOVE FINNISH FLOOR (4' A.F.F.), PLEASE INDICATE THIS |
| | ON THE RESUBMITTED REVISION. |
| | |
| | 5] PER FBC-2004 PLUMBING, SECTION 1002.1: TRAPS ARE |
| | REQUIRED FOR ALL FIXTURES, PLEASE INDICATE THEM ON THE |
| | RESUBMITTED REVISION (EXCEPTION: FIXTURES WITH INTEGRAL |
| | TRAPS (WATER CLOSETS) NEED NOT BE INDICATED ON THE |
| | RESUBMITTED REVISION.) |
| | |
| | **********IMPORTANT INFORMATION |
| | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, |
| | PLEASE REPLACE ONLY SHEETS |
| | WHICH HAVE CHANGED AND PROVIDE ONE COPY |
| | OF ALL OLD/VOIDED SHEETS FOR REFERENCE |
| | ONLY. NOTE: ONLY ONE CORRECTED DRAWING |
| | IN RED INK FOR REFERENCE FOR |
| | RESUBMITTAL. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY MIKE PERSON |
| | (561) 805-6730 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| | UNDER SUPERVISION OF K.STEVENS |
| | (561) 805-6721 |
| | |
| | |