| 2006-08-04 00:00:00 | DENIED |
| | |
| | REVIEW FOR STRUCTURAL ONLY PHASE OF 5 |
| | STORY PARKING GARAGE. |
| | |
| | 1) THE PROPERTY CONTROL NUMBER LISTED ON |
| | THE APPLICATION IS INCORRECT. THE |
| | CORRECT PCN IS 74-43-43-29-22-000-0030. |
| | |
| | 2) THE THRESHOLD INSPECTION PLAN |
| | INCORRECTLY LISTS CITY OF BOYNTON BEACH |
| | ADMINISTRATIVE AMENDMENTS TO 2004 FBC. |
| | THIS PROJECT IS LOCATED IN THE CITY OF |
| | WEST PALM BEACH. |
| | |
| | 3) THE PROPERTY LINES SHOWN ON THE |
| | SURVEY HAVE NOT BE CHANGED. THEREFORE, |
| | BASED ON FIRE SEPARATION DISTANCES THE |
| | STRUCTURE DOES NOT COMPLY WITH FBC TABLE |
| | 704.8 FOR ALLOWABLE AREA OF OPENINGS. |
| | SEE COMMENT #2 ON SECOND REVIEW FOR |
| | PERMIT #05120987. |
| | |
| | 4) THE WALL OF THE BUSINESS OCCUPANCY |
| | THAT HAS BEEN REMOVED ON SHEET A2.1.3 IS |
| | STILL SHOWN ON SHEET S1.0 OF THE |
| | STRUCTURAL DRAWINGS. PLEASE COORDINATE |
| | ARCHITECTURAL CHANGES WITH STRUCTURAL. |
| | |
| | NOTE: APPROVAL OF STRUCTURAL PHASE DOES |
| | NOT INSURE THAT A PERMIT FOR THE ENTIRE |
| | STRUCTURE WILL BE ISSUED. ALL OF THE |
| | PLAN REVIEW COMMENTS MUST BE ADDRESSED |
| | TO THE SATISFACTION OF THE CONSTRUCTION |
| | SERVICES DEPARTMENT. THE CONTRACTOR WILL |
| | BE PROCEEDING AT THEIR OWN RISK. |
| | |