2007-03-02 14:32:12BUILDING PROVISO
 1) SPIRAL STAIRS SHALL COMPLY WITH 1009.9.2.
 1.THE CLEAR WIDTH OF THE STAIRS SHALL BE NOT LESS
 THAN 26 INCHES (660 MM).
 2.THE HEIGHT OF THE RISERS SHALL NOT EXCEED 9- 1/2
 INCHES (241 MM).
 3.HEADROOM SHALL BE NOT LESS THAN 6 FEET 6 INCHES
 (1981 MM).
 4.TREADS SHALL HAVE A DEPTH NOT LESS THAN 7-1/2
 INCHES (191 MM) AT A POINT 12 INCHES (305 MM) FROM THE
 NARROWER EDGE.
 5.ALL TREADS SHALL BE IDENTICAL.
 6.HANDRAILS COMPLYING WITH SECTION 1009.11 SHALL
 BE PROVIDED ON BOTH SIDES OF THE SPIRAL STAIRWAY.