2006-07-26 00:00:00DENIED;
 1.PLEASE INCLUDE GUEST HOUSE ON THE
 PLUMBING SANITARY RISER DIAGRAM.
 2.IS WATER SERVICE TO BOTH BUILDINGS
 FROM THE SAME METER IF SO A BACKFLOW
 PREVENTER IS REQUIRED TO BE INSTALLED AT
 THE WATER METER BY THE UTILITY
 DEPARTMENT.
 3.IS WATER HEATER IN MAIN HOUSE THE HOT
 WATER SUPPLY FOR THE BACK HOUSE? IF SO
 PLEASE SHOW ON THE PLANS THE DISTANCE
 FROM THE W/H TO THE LAST FIXTURE. IF
 100' A METHOD OF MAINTAINING THE
 TEMPERATURE IN ACCORDANC WITH CHAPTER 13
 OF THE FBC-2004 BUILDING CODE MUST BE
 INSTALLED.
 4.IF A BACKFLOW IS REQUIRED THEN A MEANS
 OF THERMAL EXPANSION SHELL BE REQUIRED.
 SEE SECTION 607.3. SHOW ON DRAWINGS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695