| Plan Review Notes For Permit 06071334 |
| Permit Number |
06071334 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2007-02-06 08:05:26 | DENIED; | | | 1. SANITARY RISER DIAGRAM NOT TO CODE. | | | A) AUTOMATIC CLOTHES WASHER DRAIN IS REQUIRED | | | TO BE 3" AND MUST BE VENTED WITH C.O. AT 48". NOTE 10 | | | AND11 SHOULD BE SHOW ON THE RISER DIAGRAM. | | | B) FIRST FLOOR SINK VENT TIED INTO SECOND | | | FLOOR WASTE STACK. NOT A VENT. | | | C) WATER CLOSET NOT VENTED. | | | D) TUB NOT VENTED. | | | E) TUB NOT VENTED. | | | F)SHOWER NOT VENTED. | | | G) SECOND FLOOR KITCHEN SINK MUST DISCHARGE | | | DOWN STREAM OF THE BATHROOM GROUP. SEC.909.1. | | | H) SECOND FLOOR MASTER BATHROOM NOT DRAWN | | | CORRECTLY. | | | I)USE PROPER NAMES FOR FIXTURES. ( | | | BATHROOMS HAVE LAVATORIES NOT SINKS). | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|