| 2006-12-13 13:13:52 | DENIED BY BUILDING |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT |
| | MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. A RECORDED COPY OF NOC IS |
| | REQUIRED. |
| | |
| | 2) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. FOR THE |
| | ADDITIONAL LIVING SPACE THAT IS BEING ADDED. |
| | |
| | 3) THE LETTER FROM THE CONDO ASSOCIATION IS REQUIRED TO |
| | BE SIGNED BY THE ASSOCIATION PRESIDENT AND NOTARIZED. |
| | THIS IS REQUIRED BECAUSE THIS PROJECT AFFECTS THE |
| | EXTERIOR ENVELOPE OF THE STRUCTURE, WHICH IS OWNED BY |
| | THE CONDO ASSOCIATION. |
| | |
| | 4) THE SCOPE OF WORK FOR THIS PROJECT INCLUDES |
| | ENCLOSING AN EXISTING OPEN PATIO AFFECTING THE BUILDING |
| | ENVELOPE WHICH IS STRUCTURAL. THIS BUILDING IS A |
| | MULTI-FAMILY R-2 OCCUPANCY AND DOES NOT FALL UNDER THE |
| | EXCEPTIONS OF FS 481.229 OR 471.003.THEREFORE, THE |
| | PLANS ARE REQUIRED TO BE PREPARED, SIGNED AND SEALED BY |
| | A FLORIDA REGISTERED ARCHITECT OR ENGINEER. SEE FS 481 |
| | AND 471. |
| | |
| | 5)THE OWNER OF THE PROPERTY IS REQUIRED TO SIGN THE |
| | NOTICE OF COMMENCEMENT. THE PROPERTY APPRAISER' S |
| | RECORD INDICATE THAT BERTRAM CROCKER AND WILLIAM TIGHE |
| | ARE THE OWNERS OF THE PROPERTY. |
| | |
| | 6) SPECIFY THE POSITIVE AND NEGATIVE DESIGN WINDLOAD |
| | PRESSURES AT THE NEW SLIDING GLASS DOOR OPENING. SEE |
| | FBC 1609. |
| | |
| | 7) SPECIFY THE TYPE OF CONSTRUCTION, NUMBER OF STORIES, |
| | OCCUPANCY TYPE AND NUMBER OF UNITS FOR THE BUILDING. |
| | USE 2004 FBC NOMENCLATURE. SEE CITY AMENDMENTS TO FBC |
| | 106.1.2. |
| | |
| | 8) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE |
| | FBC EXISTING BUILDING CODE CHAPTER 3. THIS PROJECT IS A |
| | LEVEL 2 ALTERATION. |
| | |
| | 9) OPENING PROTECTION IS REQUIRED FOR THE NEW GLAZED |
| | OPENINGS. SEE FBC EXISTING BUILDING CODE SECTION 507.3 |
| | AND FBC 1609.1.4. TYPICALLY ON CONDO BUILDINGS IMPACT |
| | GLAZING IS REQUIRED, UNLESS ON THE FIRST FLOOR WHERE |
| | STORM PANELS MAY BE USED IF APPROVED BY THE BUILDING |
| | OFFICAL. IN ORDER TO INSTALL PANELS AN INSTALLATION |
| | PLAN MUST BE SUBMITTED AND APPROVED BY THE BO. SEE THE |
| | ATTACHED IMPACT PROTECTION STANDARD. |
| | |
| | 10)PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. |
| | |
| | 11)WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 12) 2004 FL. BLD CODE 1603.1.4 THE |
| | FOLLOWING INFORMATION RELATED TO WIND |
| | SHALL BE SHOWN ON THE CONSTRUCTION |
| | DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| | CATEGORY |
| | 3)- WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF. |
| | |
| | 13 ) 110.2* W. P. B. ADMINISTRATIVE |
| | CODE, INFORMATION THAT IS REQUIRED FOR |
| | RECORD KEEPING & FOR CERTIFICATE OF |
| | OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH |
| | THE PERMIT WAS ISSUED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| | WITH THE PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED |
| | IN CHAPTER 6, TABLE 601. |
| | D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| | PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| | IS REQUIRED. |
| | F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| | OF THE BUILDING PERMIT. |
| | ------------------------------------- |
| | |
| | 14)PLEASE CLARIFY HOW THE SLAB ABOVE THE ENCLOSED |
| | PATIO WILL BE WATER PROOFED. IS THERE AN OPEN PATIO |
| | ABOVE IT OR AN ENCLOSED ROOM OR WHAT?PROVIDE AN |
| | ELEVATION SHOWING THE BUILDING AT THIS LOCATION. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |
| | |
| | |
| | |