| Date |
Text |
| 2006-10-12 13:53:05 | DENIED... |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE FLORIDA |
| | STATUTES |
| | |
| | 1. ALL ARCHITECTURAL SHEETS SHALL BE SIGNED, SEALED, |
| | DATED PER SECTION 106.1, FAC 61G1-16.003 & FS |
| | 481.2055. |
| | |
| | 2. ALL ARCHITECTURAL SHEETS. THE CERTIFICATE OF |
| | AUTHORIZATION, (BUSINESS NUMBER), IS INDICATED AS |
| | DELINQUENT PER DBPR WEBSITE. THIS SHALL BE TAKEN CARE |
| | OF PRIOR TO RESUBMITTING FOR REVIEW. FAC 61G1-16.004(1) |
| | & FS 481.219. |
| | |
| | 3. SHT A-7 DETAIL #2 SHOWS A URINAL IN THE WOMEN'S |
| | TOILET ROOM. PLEASE CLARIFY. SECTION 106.1.1. - DETAIL |
| | #2 ALSO INDICATES A SINGLE DRINKING FOUNTAIN. PLEASE |
| | SHOW COMPLIANCE WITH SECTION 11-4.1.3(10)(A) PROVISIONS |
| | FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. |
| | |
| | 4. SHT A-7 DETAIL #13 NO LAV SHOWN IN THE WOMEN'S |
| | ACCESSIBLE STALL AS SHOWN ON THE FLOOR PLAN. PLEASE |
| | CORRELATE ELEVATION DETAILS WITH THE FLOOR PLAN. |
| | |
| | 5. SHT A-7 SHOW COMPLIANCE WITH THE FOLLOWING: |
| | A. 11-4.16.2 CLEAR FLOOR SPACE |
| | B. 11-4.18.3 CLEAR FLOOR SPACE |
| | C. 11-4.19.3 CLEAR FLOOR SPACE |
| | D. 11-4.19.4 EXPOSED PIPES & SURFACES |
| | E. 11-4.19.5 FAUCETS |
| | |
| | 6. SHT A-9 DETAIL #2 SHOW COMPLIANCE WITH THE |
| | FOLLOWING: |
| | A. 11-4.24.3 KNEE CLEARANCE |
| | B. 11-4.24.4 SINK DEPTH |
| | C. 11-4.24.5 CLEAR FLOOR SPACE |
| | |
| | 7. ALL PME SHEETS SHALL BE SIGNED, SEALED, DATED. |
| | SECTION 106.1, FAC 61G15-23.002 & FS 471.025. |
| | |
| | 8. SHTS P-1 & P-2. FLOOR DRAINS ARE SHOWN ON THE FLOOR |
| | PLAN IN THE MEN'S & WOMEN'S TOILET ROOMS, THE JANITOR |
| | ROOM, AND THE LOUNGE ON THE ARCHITECTURAL FLOOR PLANS, |
| | BUT NOT ON THE PLUMBING SHEETS. PLEASE CORRELATE |
| | ARCHITECTURAL SHEETS AND THE PLUMBING FLOOR PLAN AND |
| | SANITARY RISER DIAGRAM. SECTION 106.1.1. |
| | |
| | 9. SHTS P-1 & P-2 NO WATER OR SANITARY PIPING SHOWN TO |
| | THE LOUNGE SINK. PLEASE CLARIFY. SECTION 106.1.1. |
| | |
| | 10. HOT WATER SUPPLY IS REQUIRED FOR THE JANITOR SINK |
| | PER SECTION 607.1 |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |