Plan Review Notes
Plan Review Notes For Permit 06070451
Permit Number 06070451
Review Stop P
Sequence Number 1
Notes
Date Text
2006-10-12 13:53:05DENIED...
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE FLORIDA
 STATUTES
  
 1. ALL ARCHITECTURAL SHEETS SHALL BE SIGNED, SEALED,
 DATED PER SECTION 106.1, FAC 61G1-16.003 & FS
 481.2055.
  
 2. ALL ARCHITECTURAL SHEETS. THE CERTIFICATE OF
 AUTHORIZATION, (BUSINESS NUMBER), IS INDICATED AS
 DELINQUENT PER DBPR WEBSITE. THIS SHALL BE TAKEN CARE
 OF PRIOR TO RESUBMITTING FOR REVIEW. FAC 61G1-16.004(1)
 & FS 481.219.
  
 3. SHT A-7 DETAIL #2 SHOWS A URINAL IN THE WOMEN'S
 TOILET ROOM. PLEASE CLARIFY. SECTION 106.1.1. - DETAIL
 #2 ALSO INDICATES A SINGLE DRINKING FOUNTAIN. PLEASE
 SHOW COMPLIANCE WITH SECTION 11-4.1.3(10)(A) PROVISIONS
 FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING.
  
 4. SHT A-7 DETAIL #13 NO LAV SHOWN IN THE WOMEN'S
 ACCESSIBLE STALL AS SHOWN ON THE FLOOR PLAN. PLEASE
 CORRELATE ELEVATION DETAILS WITH THE FLOOR PLAN.
  
 5. SHT A-7 SHOW COMPLIANCE WITH THE FOLLOWING:
 A. 11-4.16.2 CLEAR FLOOR SPACE
 B. 11-4.18.3 CLEAR FLOOR SPACE
 C. 11-4.19.3 CLEAR FLOOR SPACE
 D. 11-4.19.4 EXPOSED PIPES & SURFACES
 E. 11-4.19.5 FAUCETS
  
 6. SHT A-9 DETAIL #2 SHOW COMPLIANCE WITH THE
 FOLLOWING:
 A. 11-4.24.3 KNEE CLEARANCE
 B. 11-4.24.4 SINK DEPTH
 C. 11-4.24.5 CLEAR FLOOR SPACE
  
 7. ALL PME SHEETS SHALL BE SIGNED, SEALED, DATED.
 SECTION 106.1, FAC 61G15-23.002 & FS 471.025.
  
 8. SHTS P-1 & P-2. FLOOR DRAINS ARE SHOWN ON THE FLOOR
 PLAN IN THE MEN'S & WOMEN'S TOILET ROOMS, THE JANITOR
 ROOM, AND THE LOUNGE ON THE ARCHITECTURAL FLOOR PLANS,
 BUT NOT ON THE PLUMBING SHEETS. PLEASE CORRELATE
 ARCHITECTURAL SHEETS AND THE PLUMBING FLOOR PLAN AND
 SANITARY RISER DIAGRAM. SECTION 106.1.1.
  
 9. SHTS P-1 & P-2 NO WATER OR SANITARY PIPING SHOWN TO
 THE LOUNGE SINK. PLEASE CLARIFY. SECTION 106.1.1.
  
 10. HOT WATER SUPPLY IS REQUIRED FOR THE JANITOR SINK
 PER SECTION 607.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]